| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
DP8110 bảng dữ liệu(PDF) 4 Page - Power-One |
|
|
|||||||||||||||||||||||||||||
DP8110 bảng dữ liệu(HTML) 4 Page - Power-One |
|
4 / 34 page ![]() DP8110 10A DC-DC Intelligent dPOL Data Sheet 8V to 14V Input •••• 0.7V to 5.5V Output BCD.00262 Rev. 1.0, 12 FEB 2013 www.power-one.com Page 4 of 34 4.3 Protection Specifications Parameter Conditions/Description Min Nom Max Units Output Overcurrent Protection Type Default Programmable Non-Latching, 130ms period Latching/Non-Latching Threshold Default Programmable in 11 steps 36 132 132 %IOUT %IOUT Threshold Accuracy -20 +20 %IOCP.SET Output Overvoltage Protection Type Default Programmable Non-Latching, 130ms period Latching/Non-Latching Threshold Default Programmable in 10% steps 110 130 130 %VO.SET %VO.SET Threshold Accuracy Measured at VO.SET=2.5V -2 2 %VOVP.SET Delay From instant when threshold is exceeded until the turn-off command is generated 6 µ s Turn Off Behavior 3 Default Programmable to Emergency Off Critical Off / Emergency Off Output Undervoltage Protection Type Default Programmable Non-Latching, 130ms period Latching/Non-Latching Threshold Default Programmable in 5% steps 75 75 90 %VO.SET %VO.SET Threshold Accuracy Measured at VO.SET=2.5V -2 2 %VUVP.SET Delay From instant when threshold is exceeded until the turn-off command is generated 6 µ s Turn Off Behavior 3 Default Programmable to Sequenced Off Sequenced / Critical Off Overtemperature Protection Type Default Programmable Non-Latching, 130ms period Latching/Non-Latching Turn Off Threshold Temperature is increasing 120 ° C Turn On Threshold Temperature is decreasing after the module was shut down by OTP 4 110 ° C Threshold Accuracy -5 5 ° C Delay From instant when threshold is exceeded until the turn-off command is generated 6 µ s Turn Off Behavior 3 Default Programmable to Sequenced Off Sequenced / Critical Off Tracking Protection (when Enabled) 3 Sequenced Off: The turn-off follows the turn-off delay and slew-rate settings; Critical Off: At turn-off both low and high switches are immediately disabled; Catastrophic Off: At turn-off the high side switch is disabled and the low side switch is enabled. 4 OTP clears when Overtemp Warning (Status Register TW bit) turns off. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |