| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ATmega1284P bảng dữ liệu(PDF) 215 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
ATmega1284P bảng dữ liệu(HTML) 215 Page - ATMEL Corporation |
|
215 / 380 page ![]() 215 8059D–AVR–11/09 ATmega1284P The TWINT Flag is set in the following situations: • After the TWI has transmitted a START/REPEATED START condition. • After the TWI has transmitted SLA+R/W. • After the TWI has transmitted an address byte. • After the TWI has lost arbitration. • After the TWI has been addressed by own slave address or general call. • After the TWI has received a data byte. • After a STOP or REPEATED START has been received while still addressed as a Slave. • When a bus error has occurred due to an illegal START or STOP condition. 19.6 Using the TWI The AVR TWI is byte-oriented and interrupt based. Interrupts are issued after all bus events, like reception of a byte or transmission of a START condition. Because the TWI is interrupt-based, the application software is free to carry on other operations during a TWI byte transfer. Note that the TWI Interrupt Enable (TWIE) bit in TWCR together with the Global Interrupt Enable bit in SREG allow the application to decide whether or not assertion of the TWINT Flag should gener- ate an interrupt request. If the TWIE bit is cleared, the application must poll the TWINT Flag in order to detect actions on the TWI bus. When the TWINT Flag is asserted, the TWI has finished an operation and awaits application response. In this case, the TWI Status Register (TWSR) contains a value indicating the current state of the TWI bus. The application software can then decide how the TWI should behave in the next TWI bus cycle by manipulating the TWCR and TWDR Registers. Figure 19-10 is a simple example of how the application can interface to the TWI hardware. In this example, a Master wishes to transmit a single data byte to a Slave. This description is quite abstract, a more detailed explanation follows later in this section. A simple code example imple- menting the desired behavior is also presented. Figure 19-10. Interfacing the Application to the TWI in a Typical Transmission 1. The first step in a TWI transmission is to transmit a START condition. This is done by writing a specific value into TWCR, instructing the TWI hardware to transmit a START START SLA+W A Data A STOP 1. Application writes to TWCR to initiate transmission of START 2. TWINT set. Status code indicates START condition sent 4. TWINT set. Status code indicates SLA+W sent, ACK received 6. TWINT set. Status code indicates data sent, ACK received 3. Check TWSR to see if START was sent. Application loads SLA+W into TWDR, and loads appropriate control signals into TWCR, makin sure that TWINT is written to one, and TWSTA is written to zero. 5. Check TWSR to see if SLA+W was sent and ACK received. Application loads data into TWDR, and loads appropriate control signals into TWCR, making sure that TWINT is written to one 7. Check TWSR to see if data was sent and ACK received. Application loads appropriate control signals to send STOP into TWCR, making sure that TWINT is written to one TWI bus Indicates TWINT set |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |