446 / 746 page ![]() Rev. 1.00, 09/03, page 408 of 704 14.5.3 Count Start Timing for Duty Measurement If a rising edge of the external event input is detected after the START bit in TWCR2 has been set to 1, a count enable signal is set. At this time, if the TWCNT input clock exists, TWCNT starts incrementing. Figure 14.5 shows the count start timing for duty measurement. TWCNT TWCNT input clock External signal 01 00 Count enable signal Internal clock Figure 14.5 Count Start Timing for Duty Measurement 14.5.4 Capture Timing during Duty Measurement When a falling edge of the external event signal is detected during duty measurement, the TWCNT value is transferred to TWICR. Figure 14.6 shows the capture timing during duty measurement. TWCNT Capture signal External signal N N-1 TWICR N n Figure 14.6 Input Capture Timing during Duty Measurement |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|