119 / 615 page ![]() Mitsubishi microcomputers M16C / 62A Group SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER Timers’ functions for three-phase motor control 1-100 Figure 1.15.5 shows the block diagram for three-phase PWM output mode. In three-phase PWM output ___ mode, the positive-phase waveforms (U phase, V phase, and W phase) and negative waveforms (U ___ ___ phase, V phase, and W phase), six waveforms in total, are output from P80, P81, P72, P73, P74, and P75 ___ as active on the “L” level. Of the timers used in this mode, timer A4 controls the U phase and U phase, ___ ___ timer A1 controls the V phase and V phase, and timer A2 controls the W phase and W phase respectively; timer B2 controls the periods of one-shot pulse output from timers A4, A1, and A2. In outputting a waveform, dead time can be set so as to cause the “L” level of the positive waveform ___ output (U phase, V phase, and W phase) not to lap over the “L” level of the negative waveform output (U ___ ___ phase, V phase, and W phase). To set short circuit time, use three 8-bit timers sharing the reload register for setting dead time. A value from 1 through 255 can be set as the count of the timer for setting dead time. The timer for setting dead time works as a one-shot timer. If a value is written to the dead time timer (034C16), the value is written to the reload register shared by the three timers for setting dead time. Any of the timers for setting dead time takes the value of the reload register into its counter, if a start trigger comes from its corresponding timer, and performs a down count in line with the clock source selected by the dead time timer count source select bit (bit 2 at 034916). The timer can receive another trigger again before the workings due to the previous trigger are completed. In this instance, the timer performs a down count from the reload register’s content after its transfer, provoked by the trigger, to the timer for setting dead time. Since the timer for setting dead time works as a one-shot timer, it starts outputting pulses if a trigger comes; it stops outputting pulses as soon as its content becomes 0016, and waits for the next trigger to come. ___ ___ The positive waveforms (U phase, V phase, and W phase) and the negative waveforms (U phase, V ___ phase, and W phase) in three-phase PWM output mode are output from respective ports by means of setting “1” in the output control bit (bit 3 at 034816). Setting “0” in this bit causes the ports to be the state of set by port direction register. This bit can be set to “0” not only by use of the applicable instruction, but _______ by entering a falling edge in the NMI terminal or by resetting. Also, if “1” is set in the positive and negative phases concurrent L output disable function enable bit (bit 4 at 034816) causes one of the pairs of U ___ ___ ___ phase and U phase, V phase and V phase, and W phase and W phase concurrently go to “L”, as a result, the port becomes the state of set by port direction register. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |