| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
HB2000ES bảng dữ liệu(PDF) 12 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
HB2000ES bảng dữ liệu(HTML) 12 Page - NXP Semiconductors |
|
12 / 34 page ![]() NXP Semiconductors KTFRDMHB2000ESEVMUG FRDM-HB2000ESEVM evaluation board KTFRDMHB2000ESEVMUG All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved. User guide Rev. 2 — 11 June 2018 12 / 34 Name Signal Jumper position Connection 1−2 MISO control through MCU SPI output J10 pin 10 (SPI_MISO) J8 MISO 2−3 MISO not connected for operation without SPI J11 CFB 1−2 CFB connected to 200 Ω resistor 1−2 VDD connected to VDDQ J14 VDDQ 2−3 VDDQ not connected 1−2 VDD supply from regulator U2 J17 VDD 2−3 VDD supply from FRDM board J18 CFB_R 1−2 CFB connected to MCU ADC input J10 pin 17 (CFB_READ) J19 FS_B 1−2 FS_B connected to the pull-up resistor J26 VDD_REG 1−2 VDD to FRDM board J15 EX_IN open IN1 and IN2 external inputs The FRDM-HB2000ESEVM, with a FRDM-KL25Z board (shipped with the kit), can evaluate the design with a GUI, any MCU with GPIO or with simple lab equipment. A FRDM-KL25Z compatible GUI and MCU program are available online at the following link: http://www.nxp.com/FRDM-HB2000ESEVM. The FRDM-HB2000ESEVM is compatible with any Arduino platform board. However, if a board other than the FRDM-KL25Z is used, MCU code must be written to work with the board. 4.7 Input signal definitions The following input signals control the outputs or functions inside the circuit. Table 5. Input signal definitions Input name Description DIS disable signal to 3-state the outputs ENBL disable signal to 3-state the output and put the part in Sleep mode IN1 logic input to control OUT1 IN2 logic input to control OUT2 MOSI master output slave input for the SPI CS_B chip select bar input for the SPI SCLK clock for the SPI 4.8 Output signal definitions The FRDM-HB2000ESEVM uses the following output signals to drive a load such as a brushed DC motor. The board provides an analog output for real-time load current monitoring. This signal allows closed-loop control of the load. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |