36 / 228 page ![]() C8051F310/1/2/3/4/5/6/7 36 Rev. 1.7 3. Global DC Electrical Characteristics Table 3.1. Global DC Electrical Characteristics –40°C to +85°C, 25 MHz System Clock unless otherwise specified. Parameter Conditions Min Typ Max Units Digital Supply Voltage VRST 1 3.0 3.6 V Digital Supply RAM Data Retention Voltage —1.5 — V Specified Operating Temperature Range –40 — +85 °C SYSCLK (system clock frequency) 02 —25 MHz Tsysl (SYSCLK low time) 18 — — ns Tsysh (SYSCLK high time) 18 — — ns Digital Supply Current—CPU Active (Normal Mode, fetching instructions from Flash) IDD (Note 3) VDD = 3.0 V, F = 25 MHz — 7.8 8.6 mA VDD = 3.0 V, F = 1 MHz — 0.38 — mA VDD = 3.0 V, F = 80 kHz — 31 — µA VDD = 3.6 V, F = 25 MHz — 10.7 12.1 mA IDD Supply Sensitivity (Note 3, Note 4) F = 25 MHz — 67 — %/V F = 1 MHz — 62 — %/V IDD Frequency Sensitivity (Note 3, Note 5) VDD = 3.0 V, F < 15 MHz, T = 25 ºC — 0.39 — mA/MHz VDD = 3.0 V, F > 15 MHz, T = 25 ºC — 0.21 — mA/MHz VDD = 3.6 V, F < 15 MHz, T = 25 ºC — 0.55 — mA/MHz VDD = 3.6 V, F > 15 MHz, T = 25 ºC — 0.27 — mA/MHz Notes: 1. Given in Table 9.1 on page 110. 2. SYSCLK must be at least 32 kHz to enable debugging. 3. Based on device characterization data, not production tested. 4. Active and Inactive IDD at voltages and frequencies other than those specified can be calculated using the IDD Supply Sensitivity. For example, if the VDD is 3.3 V instead of 3.0 V at 25 MHz: IDD = 7.8 mA typical at 3.0 V and f = 25 MHz. From this, IDD = 7.8 mA + 0.67 x (3.3 V – 3.0 V) = 8 mA at 3.3 V and f = 25 MHz. 5. IDD can be estimated for frequencies < 15 MHz by multiplying the frequency of interest by the fre- quency sensitivity number for that range. When using these numbers to estimate IDD for > 15 MHz, the estimate should be the current at 25 MHz minus the difference in current indicated by the fre- quency sensitivity number. For example: VDD = 3.0 V; F = 20 MHz, IDD = 7.8 mA – (25 MHz – 20 MHz) x 0.21 mA/MHz = 6.75 mA. 6. Idle IDD can be estimated for frequencies < 1 MHz by multiplying the frequency of interest by the frequency sensitivity number for that range. When using these numbers to estimate Idle IDD for > 1 MHz, the estimate should be the current at 25 MHz minus the difference in current indicated by the frequency sensitivity number. For example: VDD = 3.0 V; F = 5 MHz, Idle IDD = 4.8 mA – (25 MHz – 5 MHz) x 0.15 mA/MHz = 1.8 mA. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |