| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
TCAN337/G bảng dữ liệu(PDF) 20 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TCAN337/G bảng dữ liệu(HTML) 20 Page - Texas Instruments |
|
20 / 47 page ![]() 6.3.5 Fault Pin (TCAN337) If one or more of the faults (TXD-Dominant Timeout, RXD dominant Timeout, Thermal Shutdown or Undervoltage Lockout) occurs, the FAULT pin (open-drain) turns off, resulting in a high level when externally pulled up to VCC supply. TXD DTO RXD DTO Thermal Shutdown FAULT GND UV Lockout VCC P FAULT Input Figure 6-1. FAULT Pin Function Diagram and Application 6.3.6 Floating Pins The device has internal pull ups and pull downs on critical terminals to place the device into known states if the pin floats. See Table 6-1 for details on pin bias conditions. Table 6-2. Pin Bias PIN PULL UP or PULL DOWN COMMENT TXD Pull up Weakly biases TXD toward recessive to prevent bus blockage or TXD DTO triggering. STB Pull down Weakly biases STB terminal towards normal mode. S Pull down Weakly biases S terminal towards normal mode. SHDN Pull down Weakly biases SHDN terminal towards normal mode. The internal bias should not be relied on by design, especially in noisy environments, but should be considered a fall back protection. Special care needs to be taken when the device is used with MCUs using open drain outputs. TXD is weakly internally pulled up. The TXD pull up strength and CAN bit timing require special consideration when this device is used with an open drain TXD output on the microprocessor's CAN controller. An adequate external pull up resistor must be used to ensure that the TXD output of the microprocessor maintains adequate bit timing input to the CAN transceiver. 6.3.7 CAN Bus Short Circuit Current Limiting The device has several protection features that limit the short circuit current when a CAN bus line is shorted. These include CAN driver current limiting (dominant and recessive). The device has TXD dominant time out which prevents permanently having the higher short circuit current of dominant state in case of a system fault. During CAN communication the bus switches between dominant and recessive states, thus the short circuit current may be viewed either as the current during each bus state or as a DC average current. For system current and power considerations in the termination resistors and common mode choke ratings the average short circuit current should be used. The percentage dominant is limited by the TXD dominant time out and CAN protocol which has forced state changes and recessive bits such as bit stuffing, control fields, and interframe TCAN330, TCAN332, TCAN334, TCAN337 TCAN330G, TCAN332G, TCAN334G, TCAN337G SLLSEQ7F – DECEMBER 2015 – REVISED MAY 2025 www.ti.com 20 Submit Document Feedback Copyright © 2025 Texas Instruments Incorporated Product Folder Links: TCAN330 TCAN332 TCAN334 TCAN337 TCAN330G TCAN332G TCAN334G TCAN337G |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |