| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
25PE20VP bảng dữ liệu(PDF) 52 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
25PE20VP bảng dữ liệu(HTML) 52 Page - STMicroelectronics |
|
52 / 60 page ![]() DC and AC parameters M25PE20, M25PE10 52/60 Table 22. AC characteristics (50 MHz operation, T9HX (0.11µm) process(1))(2) (3) Test conditions specified in Table 16 and Table 17 Symbol Alt. Parameter Min. Typ. Max. Unit fC fC Clock Frequency for the following instructions: FAST_READ, RDLR, PW, PP, WRLR, PE, SE, SSE, DP, RDP, WREN, WRDI, RDSR, WRSR D.C. 50 MHz fR Clock Frequency for READ instructions D.C. 33 MHz tCH (4) tCLH Clock High Time 9 ns tCL (4) tCLL Clock Low Time 9 ns Clock Slew Rate 2 (peak to peak) 0.1 V/ns tSLCH tCSS S Active Setup Time (relative to C) 5 ns tCHSL S Not Active Hold Time (relative to C) 5 ns tDVCH tDSU Data In Setup Time 2 ns tCHDX tDH Data In Hold Time 5 ns tCHSH S Active Hold Time (relative to C) 5 ns tSHCH S Not Active Setup Time (relative to C) 5 ns tSHSL tCSH S Deselect Time 100 ns tSHQZ (5) tDIS Output Disable Time 8 ns tCLQV tV Clock Low to Output Valid 8 ns tCLQX tHO Output Hold Time 0 ns tWHSL (6) Write Protect Setup Time 50 ns tSHWL (6) Write Protect Hold Time 100 ns tDP (5) S to Deep Power-down 3 µs tRDP (5) S High to Standby Mode 30 µs tW Write Status Register Cycle Time 3 15 ms tPW (7) Page Write Cycle Time (256 bytes) 11 23 ms tPP (7) Page Program Cycle Time (256 bytes) 0.8 3ms Page Program Cycle Time (n bytes) int(n/8) × 0.025(8) tPE Page Erase Cycle Time 10 20 ms tSE Sector Erase Cycle Time 1 5 s tSSE SubSector Erase Cycle Time 40 150 ms tBE Bulk Erase Cycle Time 4.5 10 s 1. See Important note on page 6. 2. Preliminary data. 3. Details of how to find the Technology Process in the marking are given in AN1995, see also Section 13: Part numbering. 4. tCH + tCL must be greater than or equal to 1/ fC 5. Value guaranteed by characterization, not 100% tested in production. 6. Only applicable as a constraint for a WRSR instruction when SRWD is set at 1. 7. When using PP and PW instructions to update consecutive bytes, optimized timings are obtained with one sequence including all the bytes versus several sequences of only a few bytes (1 ≤n ≤256). 8. int(A) corresponds to the upper integer part of A. E.g. int(12/8) = 2, int(32/8) = 4 int(15.3) =16. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |