615 / 1036 page ![]() Chapter 15 Inter-Integrated Circuit (IICV3) Block Description MC9S12XE-Family Reference Manual Rev. 1.07 Freescale Semiconductor 615 clock and the SCL period it may be necessary to wait until the IIC is busy after writing the calling address to the IBDR before proceeding with the following instructions. This is illustrated in the following example. An example of a program which generates the START signal and transmits the first byte of data (slave address) is shown below: 15.7.1.3 Post-Transfer Software Response Transmission or reception of a byte will set the data transferring bit (TCF) to 1, which indicates one byte communication is finished. The IIC bus interrupt bit (IBIF) is set also; an interrupt will be generated if the interrupt function is enabled during initialization by setting the IBIE bit. Software must clear the IBIF bit in the interrupt routine first. The TCF bit will be cleared by reading from the IIC bus data I/O register (IBDR) in receive mode or writing to IBDR in transmit mode. Software may service the IIC I/O in the main program by monitoring the IBIF bit if the interrupt function is disabled. Note that polling should monitor the IBIF bit rather than the TCF bit because their operation is different when arbitration is lost. Note that when an interrupt occurs at the end of the address cycle the master will always be in transmit mode, i.e. the address is transmitted. If master receive mode is required, indicated by R/W bit in IBDR, then the Tx/Rx bit should be toggled at this stage. During slave mode address cycles (IAAS=1), the SRW bit in the status register is read to determine the direction of the subsequent transfer and the Tx/Rx bit is programmed accordingly.For slave mode data cycles (IAAS=0) the SRW bit is not valid, the Tx/Rx bit in the control register should be read to determine the direction of the current transfer. The following is an example of a software response by a 'master transmitter' in the interrupt routine. 15.7.1.4 Generation of STOP A data transfer ends with a STOP signal generated by the 'master' device. A master transmitter can simply generate a STOP signal after all the data has been transmitted. The following is an example showing how a stop condition is generated by a master transmitter. CHFLAG BRSET IBSR,#$20,* ;WAIT FOR IBB FLAG TO CLEAR TXSTART BSET IBCR,#$30 ;SET TRANSMIT AND MASTER MODE;i.e. GENERATE START CONDITION MOVB CALLING,IBDR ;TRANSMIT THE CALLING ADDRESS, D0=R/W IBFREE BRCLR IBSR,#$20,* ;WAIT FOR IBB FLAG TO SET ISR BCLR IBSR,#$02 ;CLEAR THE IBIF FLAG BRCLR IBCR,#$20,SLAVE ;BRANCH IF IN SLAVE MODE BRCLR IBCR,#$10,RECEIVE ;BRANCH IF IN RECEIVE MODE BRSET IBSR,#$01,END ;IF NO ACK, END OF TRANSMISSION TRANSMIT MOVB DATABUF,IBDR ;TRANSMIT NEXT BYTE OF DATA |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |