43 / 55 page ![]() WM9705 Production Data w PD Rev 4.4 August 2006 43 ADR[2-0] CHANNEL 000 none 001 X- plate 010 Y-plate 011 Pressure Conversion 100 BMON 101 AUXADC 110 PHONE 111 PCBEEP Table 24 Conversion Address to Channel Map If BUSY flag is enabled (BSEN bit in reg 78h set ‘1’) then the BUSY pin will remain high until the conversion in complete, whereby it will transition low. This signal is output onto pin 47, EAPD/BUSY where it may be observed by the controller if required as an interrupt. (Note that use of this BUSY flag clearly precludes use of the EAPD external amplifier power down bit, but as the WM9705 has integrated headphone amplifier with it’s own power down bit PR6 in register 26h, this should not be a problem. If BSEN is not set, then EAPD operates as normal) If SLOT method is enabled (SLEN bit in register 76h is set ‘1’) then the data is output into the chosen slot and the appropriate slot tag bit set. Choice of which slot the data is written into is made by setting bits SLT[2-0] in register 76h. The following table shows which slot versus [2-0] value. SLT[2-0] OUTPUT SLOT FOR DIGITISER DATA 000 5 001 6 010 7 011 8 100 9 101 10 110 11 Table 25 Pen ADC Slot Select When the conversion result has been read, then another conversion may be commenced as required. In the event of another conversion being requested, then the stored result from the last conversion will be overwritten when the new conversion has been completed. However, if the WAIT bit is set in register 78h, then once a conversion is complete, the current conversion result may not be written into the results register, until the previous conversion result has been read. The sequence will halt at the finish of this current conversion, waiting for the results register to be cleared. Note that this does allow the controller to slow down the rate of conversions, so effectively determining the overall rate of conversion. CONVERSION CONTROL Control of ADC conversions, and screen driving functions, is by one of three methods: • Polling method • Polled Co-ordinate method • Continuous method |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |