| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
UPD6708 bảng dữ liệu(PDF) 49 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
UPD6708 bảng dữ liệu(HTML) 49 Page - Renesas Technology Corp |
|
49 / 74 page ![]() 47 µPD6708 Table 7-4. Placing Receive Data in RDB Parameter/ Areas where RDB is read Time ( µs) Note Communication Data Mode 0 Mode 1 Mode 2 Master address When ACK bit is received in message length field 0 0 0 Control bits Message length bits Receive data (first byte) When first ACK bit is received in data field Approx. 1580 Approx. 400 Approx. 290 Receive data (second byte) When second ACK bit is received in data field Approx. 3160 Approx. 800 Approx. 580 Receive data (N-th byte) When N-th ACK bit is received in data field Approx. 1580 × N Approx. 400 × N Approx. 290 × N Note Minimum time after the “slave reception start” return code is placed in STR and an interrupt request is generated. 7.5 Broadcast Reception (1) When a broadcast reception unit receives the message length field, the master address, control bits and message length bits are placed in RDB as shown in Figure 7-6, a “broadcast reception start” return code (CH) is placed in STR, and an interrupt request is generated. Figure 7-6. Data Exchange During Broadcast Reception (Contents of RDB) (2) Each time one byte of receive data is received, it is placed in RDB. (3) Each time 20 bytes (RDB capacity) of receive data are received, if RDB is full, a “slave receive buffer full” return code (DH) is placed in STR, and an interrupt request is generated. (4) After the final data of one frame is placed in RDB, a “broadcast reception normal termination” return code (EH) is placed in STR and an interrupt request is generated. (5) If a communication error occurs during reception and communication stops without receiving all of the data transmitted from the master unit, a “termination during broadcast reception” return code (FH) is placed in STR and an interrupt request is generated. The areas where the µPD6708 places receive data, etc., in RDB are the same as those shown in Table 7-4. Master Address (12 Bits) First Byte Second Byte Third Byte Fourth Byte Onward RDB Message Length Bits Control Bits |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |