| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MMPF0200Z bảng dữ liệu(PDF) 37 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MMPF0200Z bảng dữ liệu(HTML) 37 Page - NXP Semiconductors |
|
37 / 118 page ![]() Analog Integrated Circuit Device Data Freescale Semiconductor 37 PF0200Z Functional Block Requirements and Behaviors Power Generation 3. Sleep Mode: The output voltage can be higher or lower than in normal operation, but is typically selected to be the lowest state retention voltage of a given processor; it is selected by I2C bits SW1ABOFF[5:0] for SW1A/B and by bits SWxOFF[6:0] for SW2, and SW3A/B. Voltage transitions initiated by a turn-off event are governed by the SW1ABDVSSPEED[1:0] and SWxDVSSPEED[1:0] I2C bits shown in Table 32 and Table 33, respectively. Table 30, Table 31, Table 32, and Table 33 summarize the set point control and DVS time stepping applied to all regulators. The regulators have a strong sourcing capability and sinking capability in PWM mode, therefore the fastest rising and falling slopes are determined by the regulator in PWM mode. However, if the regulators are programmed in PFM or APS mode during a DVS transition, the falling slope can be influenced by the load. Additionally, as the current capability in PFM mode is reduced, controlled DVS transitions in PFM mode could be affected. Critically timed DVS transitions are best assured with PWM mode operation. The following diagram shows the general behavior for the regulators when initiated with I2C programming, or standby control. During the DVS period the overcurrent condition on the regulator should be masked. Table 30. DVS Control Logic for SW1A/B STANDBY Set Point Selected by 0 SW1AB[5:0] 1 SW1ABSTBY[5:0] Table 31. DVS Control Logic for SW2 and SW3A/B STANDBY Set Point Selected by 0 SWx[6:0] 1 SWxSTBY[6:0] Table 32. DVS Speed Selection for SW1A/B SW1ABDVSSPEED[1:0] Function 00 25 mV step each 2.0 s 01 (default) 25 mV step each 4.0 s 10 25 mV step each 8.0 s 11 25 mV step each 16 s Table 33. DVS Speed Selection for SW2 and SW3A/B SWxDVSSPEED[1:0] Function SWx[6] = 0 or SWxSTBY[6] = 0 Function SWx[6] = 1 or SWxSTBY[6] = 1 00 25 mV step each 2.0 s 50 mV step each 4.0 s 01 (default) 25 mV step each 4.0 s 50 mV step each 8.0 s 10 25 mV step each 8.0 s 50 mV step each 16 s 11 25 mV step each 16 s 50 mV step each 32 s |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |