công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

LTC2972 bảng dữ liệu(PDF) 37 Page - Linear Technology

tên linh kiện LTC2972
Giải thích chi tiết về linh kiện  2-Channel PMBus Power System Manager Featuring Programmable Power Good Outputs
PDF  112 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  LINER [Linear Technology]
Trang chủ  http://www.linear.com
Logo LINER - Linear Technology

LTC2972 bảng dữ liệu(HTML) 37 Page - Linear Technology

Back Button LTC2972 Datasheet HTML 33Page - Linear Technology LTC2972 Datasheet HTML 34Page - Linear Technology LTC2972 Datasheet HTML 35Page - Linear Technology LTC2972 Datasheet HTML 36Page - Linear Technology LTC2972 Datasheet HTML 37Page - Linear Technology LTC2972 Datasheet HTML 38Page - Linear Technology LTC2972 Datasheet HTML 39Page - Linear Technology LTC2972 Datasheet HTML 40Page - Linear Technology LTC2972 Datasheet HTML 41Page - Linear Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 37 / 112 page
background image
LTC2972
37
2972fa
For more information www.linear.com/LTC2972
OPERATION
The OPERATION command is used to turn the unit on and off in conjunction with the CONTROL pin and ON_OFF_CONFIG.
This command register responds to the global page command (PAGE = 0xFF). The contents and functions of the data
byte are shown in the following tables. A minimum tOFF_MIN wait time must be observed between any OPERATION
commands used to turn the unit off and then back on.
OPERATION Data Contents (On_off_config_use_pmbus = 1)
SYMBOL
Action
Operation_control[1:0] Operation_margin[1:0] Operation_fault[1:0] Reserved (Read Only)
BITS
b[7:6]
b[5:4]
b[3:2]
b[1:0]
FUNCTION
Turn off immediately
00
XX
XX
00
Sequence on
10
00
XX
00
Margin low (ignore faults and warnings)
10
01
01
00
Margin low
10
01
10
00
Margin high (ignore faults and warnings
10
10
01
00
Margin high
10
10
10
00
Sequence off with margin to nominal
01
00
XX
00
Sequence off with margin low (ignore
faults and warnings)
01
01
01
00
Sequence off with margin low
01
01
10
00
Sequence off with margin high (ignore
faults and warnings)
01
10
01
00
Sequence off with margin high
01
10
10
00
Reserved
All remaining combinations
OPERATION Data Contents (On_off_config_use_pmbus = 0)
On or Off
SYMBOL
Action
Operation_control[1:0] Operation_margin[1:0]
Operation_fault[1:0]
Reserved (Read Only)
BITS
b[7:6]
b[5:4]
b[3:2]
b[1:0]
FUNCTION
Output at nominal
00, 01 or 10
00
XX
00
Margin low (ignore faults and
warnings)
00, 01 or 10
01
01
00
Margin low
00, 01 or 10
01
10
00
Margin high (ignore faults and
warnings
00, 01 or 10
10
01
00
Margin high
00, 01 or 10
10
10
00
Reserved
All remaining combinations
PMBus COMMAND DESCRIPTION



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com