| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ADAS1000-4BSTZ bảng dữ liệu(PDF) 38 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADAS1000-4BSTZ bảng dữ liệu(HTML) 38 Page - Analog Devices |
|
38 / 80 page ![]() ADAS1000-3/ADAS1000-4 Data Sheet Rev. B | Page 38 of 80 envelope and perform the peak detection needed to establish breathing (or lack thereof). Respiration measurement is available on one of the leads (Lead I, Lead II, or Lead III) or on an external path via a pair of dedicated pins (EXT_RESP_LA, EXT_RESP_RA, or EXT_RESP_LL). Only one lead measurement can be made at one time. The respiration measurement path is not suited for use as additional ECG measurements because the internal configuration and demodulation do not align with an ECG measurement. The respiration signal processing path is not reconfigurable for ECG measurements, as it is specifically designed for the respiration signal measurement. Internal Respiration Capacitors The internal respiration function uses an internal RC network (5 kΩ/100 pF), and this circuit is capable of 200 mΩ resolution (with up to 5 kΩ total path and cable impedance). The current is ac-coupled onto the same pins that the measurement is sensed back on. Figure 67 shows the measurement on Lead I, but, similarly, the measurement can be configured to measure on either Lead II or Lead III. The internal capacitor mode requires no external capacitors and produces currents of ~64 μA p-p amplitude when configured for maximum amplitude setting (±1 V) through the RESPCTRL register (see Table 30). Table 12. Maximum Allowable Cable and Thoracic Loading Cable Resistance Cable Capacitance R < 1 kΩ C < 1200 pF 1 kΩ < R < 2.5 kΩ C < 400 pF 2.5 kΩ < R < 5 kΩ C < 200 pF RTHORACIC < 2 kΩ Figure 67. Simplified Respiration Block Diagram LA CABLE ECG1_LA EXT_RESP_LA ECG2_LL EXT_RESP_LL ECG3_RA EXT_RESP_RA ADAS1000-4 OVERSAMPLED 5kΩ 5kΩ 100pF 100pF ±1V ±1V RESPIRATION DAC DRIVE + CABLE AND ELECTRODE IMPEDANCE < 5kΩ LL CABLE RA CABLE FILTER FILTER FILTER LPF RESPIRATION MEASURE RESPIRATION DAC DRIVE– HPF IN-AMP AND ANTI-ALIASING MAGNITUDE AND PHASE SAR ADC 46.5kHz TO 64kHz 46.5kHz TO 64kHz |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |