| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
A8285SLB bảng dữ liệu(PDF) 9 Page - Allegro MicroSystems |
|
|
|||||||||||||||||||||||||||||
A8285SLB bảng dữ liệu(HTML) 9 Page - Allegro MicroSystems |
|
9 / 17 page ![]() 9 Worcester, Massachusetts 01615-0036 (508) 853-5000 115 Northeast Cutoff, Box 15036 www.allegromicro.com A8285/A8287 LNB Supply and Control Voltage Regulator SDA line before the ninth clock cycle, in order to allow this handshaking to occur. During a data read, the A8285/A8287 acknowledges the address in the same way as in the data write sequence, and then retains control of the SDA line and send the data to the master. On completion of the eight data bits, the A8285/ A8287 releases the SDA line before the ninth clock cycle, in order to allow the master to acknowledge the data. If the master holds the SDA line low during this Acknowledge bit, the A8285/A8287 responds by sending another data byte to the master. Data bytes continue to be sent to the master until the master releases the SDA line during the Acknowledge bit. When this is detected, the A8285/A8287 stops sending data and waits for a stop signal. Interrupt Request. The A8285/A8287 also provides an interrupt request pin IRQ, which is an open-drain, active- low output. This output may be connected to a common IRQ line with a suitable external pull-up and can be used with other I2C devices to request attention from the master controller. The IRQ output becomes active when either the A8285/A8287 first recognizes a fault condition, or at power- on when the main supply V IN and the internal logic supply V REG reach the correct operating conditions. It is only reset to inactive when the I2C master addresses the A8285/A8287 with the Read/Write bit set (causing a read). Fault conditions are indicated by the TSD, VUV, and OCP bits in the status register (see description of OCP for conditions of use). The DIS and PNG bits do not cause an interrupt. When the mas- ter recognizes an interrupt, it addresses all slaves connected to the interrupt line in sequence, and then reads the status register to determine which device is requesting attention. The A8285/A8287 latches all conditions in the status regis- ter until the completion of the data read. The action at the resampling point is further defined in the description for each of the status bits. The bits in the status register are defined such that the all-zero condition indicates that the A8285/A8287 is fully active with no fault conditions. When V IN is initially applied, the I 2 C interface does not respond to any requests until the internal logic supply V REG has reached its operating level. Once V REG has reached this point, the IRQ output goes active, and the VUV bit is set. After the A8285/A8287 acknowledges the address, the IRQ flag is reset. Once the master reads the status registers, the registers are updated with the VUV reset. Control Register (I2C Write Register). All main func- tions of the A8285/A8287 are controlled through the I2C interface via the 8-bit Control register. This register allows selection of the output voltage and current limit, enabling and disabling the LNB output, and switching the 22 kHz tone on and off. The power-up state is 0 for all of the control functions. Bit 0 (VSEL0), Bit 1 (VSEL1), and Bit 2 (VSEL2). These provide incremental control over the voltage on the LNB output. The available voltages provide the necessary levels for all the common standards plus the ability to add line compensation in increments of 333 mV. The voltage levels are defined in the Output Voltage Amplitude Selection table. Bit 3 (VSEL3). Switches between the low-level and high- level output voltages on the LNB output. A value of 0 selects the low level voltage and a value of 1 selects the high level. The low-level center voltage is 12.709 V nominal, and the high level is 18.042 V nominal. These may be increased, in increments of 333 mV, by using the VSEL2, VSEL1, and VSEL0 control register bits. Bit 4 (ODT). When set to 1, enables the ODT feature (disables the A8285/A8287 if the overcurrent disable time is exceeded during an overcurrent condition on the output). When set to 0, the ODT feature is disabled. 0 0 0 1 0 A1 A0 1 AK D6 D5 D4 D3 D2 D1 D0 D7 NAK Status Data Address Start R Stop 1 2 3 4 5 6 7 8 9 SDA SCL IRQ Fault Event Reload Status Register Reading the Register After an Interrupt |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |