công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

A8285SLB bảng dữ liệu(PDF) 7 Page - Allegro MicroSystems

tên linh kiện A8285SLB
Giải thích chi tiết về linh kiện  LNB Supply and Control Voltage Regulator
PDF  17 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  ALLEGRO [Allegro MicroSystems]
Trang chủ  http://www.allegromicro.com
Logo ALLEGRO - Allegro MicroSystems

A8285SLB bảng dữ liệu(HTML) 7 Page - Allegro MicroSystems

Back Button A8285SLB Datasheet HTML 3Page - Allegro MicroSystems A8285SLB Datasheet HTML 4Page - Allegro MicroSystems A8285SLB Datasheet HTML 5Page - Allegro MicroSystems A8285SLB Datasheet HTML 6Page - Allegro MicroSystems A8285SLB Datasheet HTML 7Page - Allegro MicroSystems A8285SLB Datasheet HTML 8Page - Allegro MicroSystems A8285SLB Datasheet HTML 9Page - Allegro MicroSystems A8285SLB Datasheet HTML 10Page - Allegro MicroSystems A8285SLB Datasheet HTML 11Page - Allegro MicroSystems Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 17 page
background image
7
Worcester, Massachusetts 01615-0036 (508) 853-5000
115 Northeast Cutoff, Box 15036
www.allegromicro.com
A8285/A8287
LNB Supply and Control Voltage Regulator
this feature is disabled and the device is not turned off dur-
ing an overcurrent.
Status Register. The status of the A8285/A8287 read reg-
ister can be interrogated by the system master controller via
the I2C interface. Status functions include the following:
• Power Not Good (PNG). When the LNB output is enabled,
and the LNB output is below 85% of the programmed LNB
voltage, the PNG bit is set.
• Disable (DIS). Provides the status of the LNB output.
When set, this indicates that the output is disabled, either
intentionally or by a fault.
• Thermal Shutdown (TSD). When the junction tempera-
ture exceeds the maximum threshold, the thermal shutdown
bit is set, which disables the LNB output. DIS also is set.
• Overcurrent (OCP). This disables LNB output when an
overcurrent appears on the LNB output for a period greater
than the ODT (ODT must be enabled for this feature to take
effect). In addition, the DIS bit is set. Note: If an overcurrent
occurs and ODT is disabled, the A8285/A8287 will operate
in current limit indefininitely and the OCP bit will not be set.
• Undervoltage Lockout (VUV). When the input voltage
(V
IN) drops below the undervoltage threshold, the undervolt-
age bit VUV is set, disabling the output.
When V
IN is initially applied to the A8285/A8285, the VUV bit
is set, indicating that an undervoltage condition has occurred.
IRQ Flag. The IRQ flag is activated when any fault con-
dition occurs, including: thermal shutdown, overcurrent,
undervoltage, or the occurrence of a power-up sequence.
Note that the IRQ flag is not activated when either (a) the
channel is disabled (DIS), as it may have been disabled
intentionally by the master controller, or (b) if PNG is active,
as the A8285/A8287 may be starting up. Fault conditions are
stored in the status registers. Also note that the IRQ flag will
not activate when an overcurrent occurs and ODT is dis-
abled. In this condition, the device operates within I
LIM.
When the IRQ flag is activated during either of the above
fault conditions, and the system master controller addresses
the A8285/A8287 with the read/write bit set to 1, then the
IRQ flag is reset once the A8285/A8287 acknowledges the
address. When the master controller reads the data and is
acknowledged, the status registers are updated. If the fault
is removed, the A8285/A8287 is again ready for operation
(being re-enabled via a write command). Otherwise, the
controller can keep polling the A8285/A8287 until the fault
is removed.
When V
IN, is initially applied to the A8285/A8285, the I
2
C
interface will not function until the internal logic supply V
REG
has reached its operating level. Once V
REG is within toler-
ance, the VUV bit in the status register is set and the IRQ is
activated to inform the master controller of this condition.
(The IRQ is effectively acting as a power-up flag.) The IRQ
is reset when the A8285/A8287 acknowledges the address.
Once the master has read the status registers, the VUV bit is
reset. The device is then ready for operation.
I2C Interface. This is a serial interface that uses two bus
lines, SCL and SDA, to access the internal Control and
Status registers of the A8285/A8287. Data is exchanged
between a microcontroller (master) and the A8285/A8287
(slave). The clock input to SCL is generated by the master,
while SDA functions as either an input or an open drain
output, depending on the direction of the data.
VSEL3
VSEL2
VSEL1
VSEL0
LNB (V)
0
0
0
0
12.709
0
0
0
1
13.042
0
0
1
0
13.375
0
0
1
1
13.709
0
1
0
0
14.042
0
1
0
1
14.375
0
1
1
0
14.709
0
1
1
1
15.042
1
0
0
0
18.042
1
0
0
1
18.375
1
0
1
0
18.709
1
0
1
1
19.042
1
1
0
0
19.375
1
1
0
1
19.709
1
1
1
0
20.042
1
1
1
1
20.375
Output Voltage Amplitude Selection Table



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com