Back Button L9779WD-SPI Datasheet HTML 20Page - STMicroelectronics L9779WD-SPI Datasheet HTML 21Page - STMicroelectronics L9779WD-SPI Datasheet HTML 22Page - STMicroelectronics L9779WD-SPI Datasheet HTML 23Page - STMicroelectronics L9779WD-SPI Datasheet HTML 24Page - STMicroelectronics L9779WD-SPI Datasheet HTML 25Page - STMicroelectronics L9779WD-SPI Datasheet HTML 26Page - STMicroelectronics L9779WD-SPI Datasheet HTML 27Page - STMicroelectronics L9779WD-SPI Datasheet HTML 28Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 24 / 141 page
background image
Functional description
L9779WD-SPI
24/141
DocID027721 Rev 2
An additional feature for the starter delay drivers is that the starters are only shut-off after
the time delay THOLD if the SEO condition is still active.
The ignition stages are not affected by the SEO signal. This is different from the WDA signal
which additionally switches off the ignition stages.
To avoid misunderstandings one must be aware that the SEO function has nothing to do
with the WDA function and is not a part of the WDA module. The SEO function is related to
the key switch, not to the WDA function. The SEO function adds an additional safety
procedure for switching off.
Other functions than the injector stages and the starter relay drivers are not affected or
influenced by the SEO signal.
With the falling edge of KEY_ON a timer is started which disables the mentioned power
stages after 200 ms to 250 ms (typ. 225 ms). The timer is clocked by an internal oscillator.
The timer does not depend on any µC clock or function. The µC still has control on switching
on/off drivers during SEO time. This function is configured by CONFIG_REG6 register.
Figure 8. Power-down sequence without power latch mode



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com