13 / 23 page ![]() QT20.361 Q-Series 36V, 13.3A, THREE PHASE INPUT Oct. 2006 / Rev. 1.0 DS-QT20.361-EN All parameters are specified at 36V, 13.3A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 18. PROTECTION FEATURES Output protection Electronically protected against overload, no-load and short-circuits Output over-voltage protection typ. 49Vdc max. 53Vdc In case of an internal power supply defect, a redundant circuitry limits the maximum output voltage. The output shuts-down and automatically attempts to restart. Degree of protection IP 20 EN/IEC 60529 Penetration protection > 3.5mm e.g. screws, small parts Over-temperature protection yes Output shut-down with automatic restart Input transient protection MOV (Metal Oxide Varistor) and active transient filter Internal input fuse Not included See section 27.6 Note: In case of a protection event, audible noise may occur. 19. SAFETY Input / output separation SELV IEC/EN 60950-1 PELV EN 60204-1, EN 50178, IEC 60364-4-41 double or reinforced insulation Class of protection I PE (Protective Earth) connection required Isolation resistance > 5MOhm Input to output, 500Vdc PE resistance < 0.1Ohm Between housing and PE terminal Touch current (leakage current) typ. 0.38mA 3x 400Vac, 50Hz, TN mains typ. 0.54mA 3x 480Vac, 60Hz, TN mains < 0.47mA 3x 440Vac, 50Hz, TN mains < 0.7mA 3x 528Vac, 60Hz, TN mains 20. DIELECTRIC STRENGTH Fig. 20-1 Dielectric strength A B C D Type test 60s 2500Vac 3000Vac 500Vac 500Vac Factory test 5s 2500Vac 2500Vac 500Vac 500Vac Field test 5s 2000Vac 2000Vac 500Vac 500Vac A D C B L1 Input DC-ok Earth Output - + L3 L2 Type tests and factory tests: Conducted by the manufacturer. Do not repeat test in field! Rules for field test: Use appropriate test equipment which applies the voltage with a slow ramp! Connect L1, L2 and L3 together as well as all output poles. The output voltage is floating and has no ohmic connection to ground. To fulfill the PELV requirements according to EN60204-1 § 6.4.1, we recommend that either the + pole, the – pole or any other part of the output circuit shall be connected to the protective earth system. This helps to avoid situations in which a load starts unexpectedly or can not be switched off any more when unnoticed earth faults occur. 13/23 |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |