25 / 36 page ![]() Application Hints (Continued) output during these instructions is from conversion N which was started during I/O sequence 1. The Configuration Modi- fication timing diagram describes in detail the sequence of events necessary for a Data Out without Sign, Data Out with Sign, or 6/10/18/34 CCLK Acquisition time mode selection. Table 5 describes the actual data necessary to be input to the ADC to accomplish this configuration modification. The next instruction, shown in Figure 8, issued to the A/D starts conversion N+1 with 8 bits of resolution formatted MSB first. Again the data output during this I/O cycle is the data from conversion N. The number of SCLKs applied to the A/D during any conver- sion I/O sequence should vary in accord with the data out word format chosen during the previous conversion I/O se- quence. The various formats and resolutions available are shown in Table 1.In Figure 8, since 8-bit without sign MSB first format was chosen during I/O sequence 4, the number of SCLKs required during I/O sequence 5 is 8. In the follow- ing I/O sequence the format changes to 12-bit without sine MSB first; therefore the number of SCLKs required during I/O sequence 6 changes accordingly to 12. 1.3 CS Low Continuously Considerations When CS is continuously low, it is important to transmit the exact number of SCLK pulses that the ADC expects. Not do- ing so will desynchronize the serial communications to the ADC. When the supply power is first applied to the ADC, it will expect to see 13 SCLK pulses for each I/O transmission. The number of SCLK pulses that the ADC expects to see is the same as the digital output word length. The digital output word length is controlled by the Data Out (DO) format. The DO format maybe changed any time a conversion is started or when the sign bit is turned on or off. The table below de- tails out the number of clock periods required for different DO formats: Number of DO Format SCLKs Expected 8-Bit MSB or LSB First SIGN OFF 8 SIGN ON 9 12-Bit MSB or LSB First SIGN OFF 12 SIGN ON 13 16-Bit MSB or LSB first SIGN OFF 16 SIGN ON 17 If erroneous SCLK pulses desynchronize the communica- tions, the simplest way to recover is by cycling the power supply to the device. Not being able to easily resynchronize the device is a shortcoming of leaving CS low continuously. The number of clock pulses required for an I/O exchange may be different for the case when CS is left low continu- ously vs. the case when CS is cycled. Take the I/O sequence detailed in Figure 7 (Typical Power Supply Sequence) as an example. The table below lists the number of SCLK pulses required for each instruction: Instruction CS Low CS Strobed Continuously Auto Cal 13 SCLKs 8 SCLKs Read Status 13 SCLKs 8 SCLKs Read Status 13 SCLKs 8 SCLKs 12-Bit + Sign Conv 1 13 SCLKs 8 SCLKs 12-Bit + Sign Conv 2 13 SCLKs 13 SCLKs 1.4 Analog Input Channel Selection The data input on DI also selects the channel configuration for a particular A/D conversion (See Tables 2, 3, 4, 5). In Fig- ure 8 the only times when the channel configuration could be modified would be during I/O sequences 1, 4, 5 and 6. Input channels are reselected before the start of each new conver- sion. Shown below is the data bit stream required on DI, dur- ing I/O sequence number 4 in Figure 8, to set CH1 as the positive input and CH0 as the negative input for the different versions of ADCs: Part Number DI Data DI0 DI1 DI2 DI3 DI4 DI5 DI6 DI7 ADC12L030 LHL L HL X X ADC12L032 LHL L HL X X ADC12L034 L H LLL H L X ADC12L038 L H LLLL H L Where X can be a logic high (H) or low (L). 1.5 Power Up/Down The ADC may be powered down at any time by taking the PD pin HIGH or by the instruction input on DI (see Tables 5, 6, and the Power Up/Down timing diagrams). When the ADC is powered down in this way the circuitry necessary for an A/D conversion is deactivated. The circuitry necessary for digital I/O is kept active. Hardware power up/down is con- trolled by the state of the PD pin. Software power up/down is controlled by the instruction issued to the ADC. If a software power up instruction is issued to the ADC while a hardware power down is in effect (PD pin high) the device will remain DS011830-37 FIGURE 8. Changing the ADC’s Conversion Configuration www.national.com 25 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |