| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
H7CX-R11W-N bảng dữ liệu(PDF) 24 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
H7CX-R11W-N bảng dữ liệu(HTML) 24 Page - Omron Electronics LLC |
|
24 / 56 page ![]() 24 H7CX-A @-N Counter Note: 1. Counting cannot be performed during reset/reset 1 input. 2. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF. 3. If there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered. 4. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON. 5. The set value is from −99999 to 999999. One-shot output Self-holding output Instantaneous (equals) output (The one-shot output time can be set in the range 0.01 to 99.99s.) Input mode Operation after count completion UP/DOWN A, B, C Output mode setting K-2 The display continues to increase/ decrease until the overflow or underflow value is reached. One-shot output only. D The display continues to increase/ decrease until the overflow or underflow value is reached. The outputs are ON while the count is equal. L The display continues to increase/ decrease until the overflow or underflow value is reached. OUT1 is held while the present value is less than or equal to set value 1. OUT2 is held while the present value is greater than or equal to set value 2. H The display continues to increase/ decrease until the overflow or underflow value is reached. OUT1 is held while the present value is greater than or equal to set value 1. OUT2 is held while the present value is greater than or equal to set value 2. * H mode is available only when using a 6- digit model as a 2-stage counter. 0 −99999 Reset/ reset 1 OUT1 OUT2 999999 Set value 2 Set value 1 0 −99999 Reset/ reset 1 OUT1 OUT2 999999 Set value 2 Set value 1 0 −99999 Reset/ reset 1 OUT1 OUT2 999999 Set value 2 Set value 1 0 −99999 Reset/ reset 1 OUT1 OUT2 999999 Set value 2 Set value 1 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |