| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
AN3981 bảng dữ liệu(PDF) 31 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN3981 bảng dữ liệu(HTML) 31 Page - STMicroelectronics |
|
31 / 54 page ![]() AN3981 STP24DP05 Doc ID 022217 Rev 1 31/54 For proper device operation, the entering sequence must be followed by a resuming sequence as it is not possible to insert consecutive equal sequences. Figure 36. Example of error detection with the STP24DP05 Figure 36 shows an example of error detection where OUT15 and OUT0 are faulty, whereas all other outputs are considered good. 4.6.3 Correctness of the error detection results It is important to underline that the result of the diagnostic process must be compared with the data loaded into the shift register. In fact, if a channel is not switched on, the result of the detection is “0” anyway. It is recommended to follow the approach shown in Figure 26. Figure 34. Digital key for entering error detection mode in 32-bit LED drivers Figure 35. Digital key for exiting error detection mode in 32-bit LED drivers |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|