41 / 51 page ![]() AN2208 7 Test results 41/51 Loss of function was observed during the test on input lines, but is considered as normal behavior because the conducted voltage was too high and optocoupler input channels were switched. Note: B means a temporary degradation or loss of function or performance, with an automatic return to normal operation. Table 11. EMC test IEC 61000-4-6 conducted immunity test results (VN340SP RDB) IEC 61000-4-6 Test Condition VN340SP RDB 1/2 VN340SP RDB 2/2 Power supply Input ON 10V OK 10V OK Input OFF 10V OK 10V OK Switch @ 1Hz 10V OK 10V OK Output of the RDB Input ON 10V OK 10V OK Input OFF 10V OK B 10V OK B Switch @ 1Hz 10V OK 10V OK Input of the RDB Input ON 10V OK 10V OK Input OFF 10V OK B 10V OK B Switch @ 1Hz 10V OK 10V OK |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|