| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
TL-T2Y2 bảng dữ liệu(PDF) 12 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
TL-T2Y2 bảng dữ liệu(HTML) 12 Page - Omron Electronics LLC |
|
12 / 14 page ![]() Proximity Sensors Technical Guide Note: When AND/OR connections are used with Proximity Sensors, the effects of erroneous pulses or leakage current may prevent use. Verify that there are no problems before use. Extending Cable Length The cable of a Built-in Amplifier Sensor can be extended to a maximum length of 200 m with each of the standard cables (excluding some models). For Separate Amplifier Sensors (E2C-EDA, E2C, E2J, E2CY), refer to the specific precautions for individual products. Bending the Cable If you need to bend the cable, we recommend a bend radius that is at least 3 times the outer diameter of the cable (with the exception of coaxial and shielded cables). Cable Tensile Strength In general, do not subject the cable to a tension greater than that indicated in the following table. Note: Do not subject a shielded cable or coaxial cable to tension. Separating High-voltage Lines Using Metal Conduits If a power line is to be located near the Proximity Sensor cable, use a separate metal conduit to prevent malfunction or damage. (Same for DC models.) Example of Connection with S3D2 Sensor Controller Using the S3D2 Sensor Controller Connecting to a Relay Load Note: DC 2-Wire Sensors have a residual voltage of 3 V. Check the operating voltage of the relay before use. The residual voltage of the E2E-XD-M1J-T is 5 V. Model Type of connection Connection Description DC 3-wire AND (series connection) Keep the number of connected Sensors (N) within the range of the following equation. iL + (N - 1) × i ≤ Upper limit of Proximity Sensor control output VS - N × VR ≥ Operating load voltage Note: When an AND circuit is connected, the operation of Proximity Sensor B causes power to be supplied to Proximity Sensor A, and thus erroneous pulses (approximately 1 ms) may be generated in A when the power is turned ON. For this reason, take care when the load has a high response speed because malfunction may result. OR (parallel connection) For Sensors with a current output, a minimum of three OR connections is pos- sible. Whether or not four or more connections is possible depends on the model. (B) (A) Vs i + + OUT OUT - - iL i Load Example: A maximum of two Sensors can be used when an MY (24-VDC) Relay is used for the load. N : Number of Sensors that can be con- nected VR: Residual output voltage of Sensor VS: Power supply voltage i : Current consumption of Sensor iL: Load current - OUT OUT - + + Vs Load Cable diameter Tensile strength Less than 4 mm 30 N max. 4 mm min. 50 N max. DC 2-Wire Sensors DC 3-Wire Sensors 5 2 4 1 6 3 11 8 10 7 12 9 Brown OUT Blue 0 V S3D2 Operation can be reversed with the signal input switch on the S3D2. Blue Brown 24 VDC X 5 2 4 1 6 3 11 8 10 7 12 9 Black OUT Blue 0 V Brown +12 V S3D2 Operation can be reversed with the signal input switch on the S3D2. http://www.ia.omron.com/ C-7 (c)Copyright OMRON Corporation 2008 All Rights Reserved. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |