| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ZSSC3036CC1C bảng dữ liệu(PDF) 25 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
ZSSC3036CC1C bảng dữ liệu(HTML) 25 Page - List of Unclassifed Manufacturers |
|
25 / 49 page ![]() ZSSC3036 Low-Power 16-Bit Sensor Signal Conditioner IC Data Sheet May 28, 2013 © 2013 Zentrum Mikroelektronik Dresden AG — Rev. 1.20 All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice. 25 of 49 Command (Byte) Return Description Normal Mode Command Mode AAHEX — Write_ChecksumC If not yet written, the checksum for the valid user MTP page is cal- culated and written to MTP. no yes ACHEX 16-bit fully corrected bridge measurement data + 16-bit corrected internal temperature Measure Triggers full measurement cycle (AZBM, BM, AZTM, and TM, as described in section 3.2) and calculation and storage of data in interface (configurations from MTP). yes yes FXHEX Status followed by last data NOP Only valid for SPI (see 3.5.1 and 3.5.2). yes yes Table 3.2 Get_Raw Commands Command Measurement AFE Configuration Register A0HEX followed by 0000HEX BM – Bridge Measurement BM_Config A1HEX followed by ssssHEX BM – Bridge Measurement ssss is the user’s configuration setting for the measure- ment provided via the interface. The format and pur- pose of configuration bits must be according to the definitions for BM_Config. A2HEX followed by 0000HEX BM-AZBM – Auto-Zero Corrected Bridge Measurement 1) BM_Config A3HEX followed by ssssHEX BM-AZBM – Auto-Zero Corrected Bridge Measurement 2) ssss is the user’s configuration setting for the measure- ment provided via the interface. The format and pur- pose of configuration bits must be according to the definitions for BM_Config. A4HEX followed by 0000HEX TM – Temperature Measurement ZMDI-defined register A5HEX followed by ssssHEX TM – Temperature Measurement ssss is the user’s configuration setting for the measure- ment provided via the interface. The format and pur- pose of configuration bits must be according to the definitions for BM_Config being valid for temperature measurement in this case (bits [15:13] will be ignored). A6HEX followed by 0000HEX TM-AZTM – Auto-Zero Corrected Temperature Measurement 1) ZMDI-defined register A7HEX followed by ssssHEX TM-AZTM – Auto-Zero Corrected Temperature Measurement 2) ssss is the user’s configuration setting for the measure- ment provided via the interface. The format and pur- pose of configuration bits must be according to the definitions for BM_Config being valid for temperature measurement in this case (bits [15:13] will be ignored). 1) Recommended for raw data collection during calibration coefficient determination using pre-programmed (in MTP) measurement setups. 2) Recommended for raw data collection during calibration coefficient determination using un-programmed (not in MTP), external measurement setups; e.g., for evaluation purposes. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |