Back Button LNBH26 Datasheet HTML 21Page - STMicroelectronics LNBH26 Datasheet HTML 22Page - STMicroelectronics LNBH26 Datasheet HTML 23Page - STMicroelectronics LNBH26 Datasheet HTML 24Page - STMicroelectronics LNBH26 Datasheet HTML 25Page - STMicroelectronics LNBH26 Datasheet HTML 26Page - STMicroelectronics LNBH26 Datasheet HTML 27Page - STMicroelectronics LNBH26 Datasheet HTML 28Page - STMicroelectronics LNBH26 Datasheet HTML 29Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 25 / 38 page
background image
LNBH26
I²C interface protocol
Doc ID 022771 Rev 1
25/38
Table 10.
DATA 4 (Read/Write register. Register address = 0X5)
Bit
Name
CH
Value
Description
Bit 0
(LSB)
EN_IMON-
A
A
1
IMON diagnostic function is enabled. (VOUT is set to 21 V typ.)
0
IMON diagnostic function is disabled. Keep always at “0” if IMON is not used.
Bit 1
N/A
0
Reserved. Keep to “0”
Bit 2
N/A
0
Reserved. Keep to “0”
Bit 3
OLR
A/B
1
In the case of overload protection activation (OLF=1), all VSEL bits are reset
to “0” and LNB relevant output (VOUT pin) is disabled. The VSEL bits must be
set again by the master after the overcurrent condition is removed (OLF=0).
0
In the case of overload protection activation (OLF=1) the LNB output (VOUT
pin) is automatically enabled as soon as the overload condition is removed
(OLF=0) with the previous VSEL bit setting.
Bit 4
EN_IMON-
B
B
1
IMON diagnostic function is enabled
0
IMON diagnostic function is disabled. Keep always at “0” if IMON is not used.
Bit 5
N/A
0
Reserved. Keep to “0”
Bit 6
THERM
A/B
1
If thermal protection is activated (OTF=1), all VSEL bits are reset to “0” and
LNB output (VOUT pin) is disabled (both section A & B). The VSEL bits must
be set again by the master after the overtemperature condition is removed
(OTF=0).
0
In the case of thermal protection activation (OTF=1) the LNB output (VOUT
pin) is automatically enabled as soon as the overtemperature condition is
removed (OTF=0) with the previous VSEL bit setting.
Bit 7
(MSB)
COMP
1
DC-DC converter compensation set to use HIGH E.S.R. capacitors (VUP pin)
0DC-DC converter compensation set to use LOW E.S.R. capacitors (VUP pin)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com