14 / 22 page ![]() O BS O LE TE N o D ire ct R ep la ce m en t Al te rn at iv e: FM 31 64 FM3130 Integrated RTC/Alarm with 64Kb FRAM Rev. 3.2 Sept. 2011 Page 14 of 22 S A Slave Address 0 Address MSB A Data Byte A P By Master By FM3130 Start Address & Data Stop Acknowledge Address LSB A Figure 7. Single Byte Memory Write S A Slave Address 0 Address MSB A Data Byte A P By Master By FM3130 Start Address & Data Stop Acknowledge Address LSB A Data Byte A Figure 8. Multiple Byte Memory Write Memory Read Operation There are two types of memory read operations. They are current address read and selective address read. In a current address read, the FM3130 uses the internal address latch to supply the address. In a selective read, the user performs a procedure to first set the address to a specific value. Current Address & Sequential Read As mentioned above the FM3130 uses an internal latch to supply the address for a read operation. A current address read uses the existing value in the address latch as a starting place for the read operation. The system reads from the address immediately following that of the last operation. To perform a current address read, the bus master supplies a slave address with the LSB set to 1. This indicates that a read operation is requested. After receiving the complete device address, the FM3130 will begin shifting data out from the current address on the next clock. The current address is the value held in the internal address latch. Beginning with the current address, the bus master can read any number of bytes. Thus, a sequential read is simply a current address read with multiple byte transfers. After each byte the internal address counter will be incremented. Each time the bus master acknowledges a byte, this indicates that the FM3130 should read out the next sequential byte. There are four ways to terminate a read operation. Failing to properly terminate the read will most likely create a bus contention as the FM3130 attempts to read out additional data onto the bus. The four valid methods follow. 1. The bus master issues a NACK in the 9 th clock cycle and a Stop in the 10 th clock cycle. This is illustrated in the diagrams below and is preferred. 2. The bus master issues a NACK in the 9 th clock cycle and a Start in the 10 th. 3. The bus master issues a Stop in the 9 th clock cycle. 4. The bus master issues a Start in the 9 th clock cycle. If the internal address reaches the top of memory, it will wrap around to 0000h on the next read cycle. The figures below show the proper operation for current address reads. Selective (Random) Read There is a simple technique that allows a user to select a random address location as the starting point for a read operation. This involves using the first three bytes of a write operation to set the internal address followed by subsequent read operations. To perform a selective read, the bus master sends out the slave address with the LSB set to 0. This specifies a write operation. According to the write protocol, the bus master then sends the address bytes that are loaded into the internal address latch. After the FM3130 acknowledges the address, the bus master |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |