85 / 204 page ![]() 2011 Microchip Technology Inc. Preliminary DS41576A-page 85 PIC12F752/HV752 11.1 Fundamental Operation The COG generates a two output complementary PWM waveform from rising and falling event sources. In the simplest configuration, the rising and falling event sources are the same signal, which is a PWM signal with the desired period and duty cycle. The COG converts this single PWM input into a dual complemen- tary PWM output. The frequency and duty cycle of the dual PWM output match those of the single input PWM signal. The off-to-on transition of each output can be delayed from the on-to-off transition of the other output, thereby, creating a time immediately after the PWM transition where neither output is driven. This is referred to as dead time and is covered in Section 11.5 “Dead-Band Control”. A typical operating waveform, with dead band, generated from a single CCP1 input is signal is shown in Figure 11-2. The COG can also generate a PWM waveform from a periodic rising event and a separate falling event. In this case, the falling event is usually derived from analog feedback within the external PWM driver circuit. In this configuration, high power switching transients may trigger a false falling event that needs to be blanked out. The COG can be configured to blank falling (and rising) event inputs for a period of time immediately following the rising (and falling) event drive output. This is referred to as input blanking and is covered in Section 11.6 “Blanking Control”. It may be necessary to guard against the possibility of circuit faults or a feedback event arriving too late or not at all. In this case, the active drive must be terminated before the fault condition causes damage. This is referred to as auto-shutdown and is covered in Section 11.8 “Auto-shutdown Control”. The COG can be configured to operate in phase delayed conjunction with another PWM. The active drive cycle is delayed from the rising event by a phase delay timer. Phase delay is covered in more detail in Section 11.7 “Phase Delay”. A typical operating waveform, with phase delay and dead band, generated from a single CCP1 input is shown in Figure 11-3. 11.2 Clock Sources The COG clock is used as the reference clock to the various timers in the peripheral. Timers that use the COG clock include: • Rising and falling dead-band time • Rising and falling blanking time • Rising event phase delay Clock sources available for selection include: •8 MHz HFINTOSC • Instruction clock (Fosc/4) • System clock (Fosc) The clock source is selected with the GxCS<1:0> bits of the COGxCON0 register (Register 11-1). 11.3 Selectable Event Sources The COG uses two independently selectable event sources to generate the complementary waveform: • Rising edge source • Falling edge source The rising edge source is selected with the GxRS<2:0> bits and the falling edge source is selected with the GxFS<2:0> bits. Selection control bits for both sources are located in the COGxCON1 register (Register 11-2). 11.3.1 RISING EDGE EVENT The rising edge event starts the PWM output active duty cycle period. The rising edge event is the low-to-high transition of the selected rising edge source. When the phase delay and rising edge dead-band time values are zero, the rising event output starts immediately. Otherwise, the rising event output is delayed. The rising event output causes all the following actions: • Clear COGxOUT1. • Start rising edge blanking counter (if enabled). • Start rising edge dead-band counter (if enabled and after phase delay, if that also is enabled). • Set COGxOUT0 output after dead-band counter expires. 11.3.2 FALLING EDGE EVENT The falling edge event terminates the PWM output active duty cycle period. The falling edge event is the high-to-low transition of the selected falling edge source. When the falling edge dead-band time value is zero, the falling event output starts immediately. Otherwise, the rising event output is delayed. The falling edge event output causes all the following actions: • Clear COGxOUT0. • Start rising edge event input blanking (if enabled). • Start falling edge dead-band counter (if enabled). • Set COGxOUT1 output after dead-band counter expires. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |