| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ATtiny43U bảng dữ liệu(PDF) 42 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
ATtiny43U bảng dữ liệu(HTML) 42 Page - ATMEL Corporation |
|
42 / 182 page ![]() 42 8048B–AVR–03/09 ATtiny43U Figure 8-7. Typical Output Voltage of Boost Converter at Constant Full Duty Cycle. See section “Software Control of Boost Converter” on page 42 for instructions on how to turn on and off duty cycle control. The use of Full Duty Cycle mode is recommended only at low load currents. 8.4 Overload Behaviour The output is considered overloaded when the load current, I LOAD, exceeds the maximum given in Table 20-7 on page 159. During an overload condition the boost converter operates at maxi- mum duty cycle and can no longer regulate V CC. If the overload condition prevails the output voltage will drop as load current increases. If V CC drops below its minimum level the converter will switch to Start Mode. In Start Mode the converter has a low load current capability, which means nearly all overload current will be drained straight from the battery (or other power source) via the inductor and the diode. The resistance of the inductor is typically very low and, provided the voltage of the power source remains constant, the output voltage during overload will stabilise to battery voltage, V BAT, minus the forward voltage drop, VF, of the diode used. 8.5 Software Control of Boost Converter The boost converter is an independent hardware module that requires no interaction by the microcontroller, although some features can be controlled by firmware. Features that can be controlled by firmware are described in the following sections. 8.5.1 Stopping the Boost Converter The device firmware can stop the boost converter on demand. When issued a stop signal, the boost converter will exit Active Mode and enter Stop Mode, as illustrated in Figure 8-3 on page 37. This procedure allows the device to read true battery voltage using the on-board ADC, assess if the voltage is sufficient for the selected battery chemistry and then control the boost converter accordingly. VCC FDC = ON FDC = OFF DUTY CYCLE |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |