221 / 238 page ![]() Rev.1.00 Oct 20, 2004 page 209 of 222 M16C/1N Group REJ090007-0100Z 20. Precautionary Notes in Using the Device 20.3 Timer 20.3.1 Timer 1 1. Even if the prescaler 1 and Timer 1 are read out simultaneously in word-size, these registers are read byte-by-byte in the microcomputer. Consequently, the timer value may be updated during the period these two registers are being read. 20.3.2 Timers X, Y and Z 1. These timers stop counting after reset. Therefore, set values to Timer (X, Y, Z) and prescaler (X, Y, Z) before starting counting. 2. Even if prescaler (X, Y, Z) and Timer (X, Y, Z) are read out simultaneously in word-size, these registers are read byte-by-byte in the microcomputer. Consequently, the timer value may be up- dated during the period these two registers are being read. 20.3.3 Timer X 1. Using in the timer X pulse period measurement mode, the effectual edge reception flag and the timer X under flow flag are set to "0" by writing a "0" in a program. Writing a "1" has no effect. Write "1" in the other flag by using the MOV instruction when you make the flag of either one side "0" by program. (The clearance of the flag which isn't intend can be prevented.) Example: MOV.B #10XXXXXXB,008BH 2. When changing to the timer X pulse period measurement mode from other mode, the contents of the effectual edge reception flag and the timer X under flow flag are indetermind. Write "0" in the effectual edge reception flag and the timer X under flow flag before starting the timer. 3. In the timer X pulse period measurement mode, use the MOV instruction to stop the timer. Example: MOV.B #1100X00B,008BH 20.3.4 Timer Y 1. When count is stopped by writing "0" to the timer Y count start flag, the timer reloads the value of reload register and stops. Therefore, the timer count value should be read out before the timer stops. 2. When count is stopped by writing "0" to the timer Y count start flag, the timer Y interrupt request bit becomes "1" and an interrupt may occur. Thus, disable interrupts before the timer stops. Further- more, set the Timer Y interrupt request bit to "0" before starting counting again. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |