154 / 179 page ![]() 154/179 ST92141 - ANALOG TO DIGITAL CONVERTER (ADC) REGISTER DESCRIPTION (Cont’d) CONTROL LOGIC REGISTER (CLR) The Control Logic Register (CLR) manages the ADC’s logic. Writing to this register will cause the current conversion to be aborted and the autoscan logic to be re-initialized. CLR is programmable as follows: CONTROL LOGIC REGISTER (CLR) R253 - Read/Write Register Page: 63 Reset Value: 0000 0000 (00h) Bit 7:5 = SC[2:0]: Start Conversion Address. These 3 bits define the starting analog input chan- nel (Autoscan mode). The first channel addressed by SC[2:0] is converted, then the channel number is incremented for the successive conversion, until channel 7 (111) is converted. When SC2, SC1 and SC0 are all set, only channel 7 will be converted. Bit 4 = EXTG: External Trigger Enable. This bit is set and cleared by software. 0: External trigger disabled. 1: External trigger enabled. Allows a conversion sequence to be started on the subsequent edge of the external signal applied to the EXTRG pin (when enabled as an Alternate Function). Bit 3 = INTG: Internal Trigger Enable. This bit is set and cleared by software. 0: Internal trigger disabled. 1: Internal trigger enabled. Allows a conversion se- quence to be started, synchronized by an inter- nal signal (On-chip Event signal) from a Multi- function Timer peripheral. Both External and Internal Trigger inputs are inter- nally ORed, thus avoiding Hardware conflicts; however, the correct procedure is to enable only one alternate synchronization input at a time. Note: The effect of either synchronization mode is to set the START/STOP bit, which is reset by hard- ware when in SINGLE mode, at the end of each sequence of conversions. Requirements: The External Synchronisation In- put must receive a low level pulse wider than an INTCLK period and, for both External and On-Chip Event synchronisation, the repetition period must be greater than the time required for the selected sequence of conversions. Bit 2 = POW: Power Up/Power Down. This bit is set and cleared by software. 0: Power down mode: all power-consuming logic is disabled, thus selecting a low power idle mode. 1: Power up mode: the A/D converter logic and an- alog circuitry is enabled. Bit 1 = CONT: Continuous/Single. 0: Single Mode: a single sequence of conversions is initiated whenever an external (or internal) trigger occurs, or when the ST bit is set by soft- ware. 1: Continuous Mode: the first sequence of conver- sions is started, either by software (by setting the ST bit), or by hardware (on an internal or ex- ternal trigger, depending on the setting of the INTG and EXTG bits); a continuous conversion sequence is then initiated. Bit 0 = ST: Start/Stop. 0: Stop conversion. When the A/D converter is running in Single Mode, this bit is hardware re- set at the end of a sequence of conversions. 1: Start a sequence of conversions. 70 SC2 SC1 SC0 EXTG INTG POW CONT ST 9 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |