| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ST92141 bảng dữ liệu(PDF) 149 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST92141 bảng dữ liệu(HTML) 149 Page - STMicroelectronics |
|
149 / 179 page ![]() 149/179 ST92141 - ANALOG TO DIGITAL CONVERTER (ADC) ANALOG TO DIGITAL CONVERTER (Cont’d) On devices where two A/D Converters are present they can be triggered from the same source. 7.6.2.3 Analog Watchdogs Two internal Analog Watchdogs are available for highly flexible automatic threshold monitoring of external analog signal levels. Analog channels 6 and 7 monitor an acceptable voltage level window for the converted analog in- puts. The external voltages applied to inputs 6 and 7 are considered normal while they remain below their respective Upper thresholds, and above or at their respective Lower thresholds. When the external signal voltage level is greater than, or equal to, the upper programmed voltage limit, or when it is less than the lower programmed voltage limit, a maskable interrupt request is gen- erated and the Compare Results Register is up- dated in order to flag the threshold (Upper or Low- er) and channel (6 or 7) responsible for the inter- rupt. The four threshold voltages are user pro- grammable in dedicated registers (08h to 0Bh) of the ADC register page. Only the 4 MSBs of the Compare Results Register are used as flags, each of the four MSBs being associated with a threshold condition. Following a reset, these flags are reset. During normal ADC operation, the CRR bits are set, in or- der to flag an out of range condition and are auto- matically reset by hardware after a software reset of the Analog Watchdog Request flag in the ICR Register. 7.6.2.4 Power Down Mode Before enabling an A/D conversion, the POW bit of the Control Logic Register must be set; this must be done at least 60µs before the first conversion start, in order to correctly bias the analog section of the converter circuitry. When the ADC is not required, the POW bit may be reset in order to reduce the total power con- sumption. This is the reset configuration, and this state is also selected automatically when the ST9 is placed in Halt Mode (following the execution of the halt instruction). Figure 79. A/D Trigger Source Converter External Trigger On Chip Event (Internal trigger) A/D 0 EXTRG pin MFT 0 A/D 1 Analog Voltage Upper threshold Lower threshold Normal Area (Window Guarded) 9 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |