| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ST52T301 bảng dữ liệu(PDF) 42 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST52T301 bảng dữ liệu(HTML) 42 Page - STMicroelectronics |
|
42 / 100 page ![]() Bit Name Value Description 0TE 0 Transmission DISABLED 1 Transmission ENABLED 1RE 0 Receiver DISABLED 1 Receiver ENABLED 2 M 00 8, No Parity, 1 bit stop 01 8, No Parity, 2 bit stop 3 10 8, Parity, 1 bit stop 11 9, No Parity, 1 bit stop 4T8 0 Parity Odd, if Parity is selected (M = 10); otherwise 9th Data bit 1 Parity Even, if Parity is selected (M = 10); otherwise 9th Data bit 5 BRSL 000 600 Hz 001 1200 Hz 010 2400 Hz 6 011 4800 Hz 100 9600 Hz 101 19200 Hz 7 110 38400 Hz 111 External Clock Table 9.1 Configuration Register 3 Setting the START condition,the Noise error and the Frame error. When the SCI Receiver is in IDLE status, it is waiting for the START condition, that is obtained with a logic level 0, consecutive to a logic level 1. This condition is detected,if,with thefixed sampling time, three logic levels 0 are sampled after three logic levels 1. The recognition of the START bit forces the SCI Receiver Block to enter in an data acquisition sequence, according to serial mode. The 2 bits, M, of the ConfigurationRegister 3 allow to definethe serial mode with the conventionshown in table 9.2. The bit, T8, in case of M = 10is used to setthe parity check to perform, as indicated in the previous table 9.2. The recognition of STOP condition allows to transfer the received data, from Recovery Bufferto SCDR_RX buffer, adding the eventual ninth data bit, according to the meaning shown in the previous table 9.2. After this operation, RXF flag of SCI Status Input Register 8 (fig. 9.3) is set to logic level 1. The Control Unit reads the data from SCDR_RX buffer (in read-only mode) with SRX instruction and provides a reset at logic level 0 to RDRF flag. If a data of Recovery Buffer is ready to be transferred into SCDR_RX buffer, but the previous one was not yet read by the Core, an OVERRUN Error takes place: the status flag OVERR indicates the error condition. In this case the information stored in SCDR_RX buffer is not altered, but the one that has caused the OVERRUN error can be overwritten by a new data coming from the serial data line. Recovery Buffer Block This block is structured as a synchronised finite state machine on the CLOCK_RX signal falling edge. When the Recovery Buffer Block is in IDLE state it waits for the reception of the correct 1 and 0 sequence representing the START. The recognition takes place by sampling the input RxD at CLOCK_RX f requency, that has a frequency 16 times higher than CLOCK_TX. For this reason, while the external transmitter sends a single bit, the Recovery Buffer Block samples 16 states (from SAMPLE1 to SAMPLE16). 42/99 ST52T301/E301 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |