| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
CN-14A-R-C2 bảng dữ liệu(PDF) 6 Page - Panasonic Semiconductor |
|
|
|||||||||||||||||||||||||||||
CN-14A-R-C2 bảng dữ liệu(HTML) 6 Page - Panasonic Semiconductor |
|
6 / 20 page ![]() 5 Full range of performance and functions in a compact body Notes: 1) Hysteresis can be fixed to one of eight different levels. 2) “ ” or “ ” appears in the sub display for comparative output 1, and “ ” or “ ” appears for comparative output 2. Note: “ ” or “ ” appears in the sub display for comparative output 1, and “ ” or “ ” appears for comparative output 2. For low pressure <For low pressure> For high pressure All lineup models are compound pressure types No sensor settings are required to switch between positive pressure and negative pressure, so that the number of registered part numbers can be decreased. High performance accomplished The low pressure type displays measurements in 0.1 kPa at a resolution of 1/2,000 and has a response time of 2.5 ms (variable up to 5,000 ms), ±0.5 % F.S. temperature characteristics and ±0.1 % F.S. repeatability, achieving high detection performance. Ideal for applications such as suction. No mis- operations due to vacuum breakdown occur. Equipped with independent dual output Equipped with two independent comparative outputs, and separate sensing modes can be selected for each of them. Since there are two comparative outputs, one of the comparative outputs can even be used for alarm output. In addition, output, which is not being used, can be disabled. This mode is used for comparative output ON / OFF control. EASY mode H (Hysteresis) H: Fixed P 0 ON OFF Comparative output Lo Hi 0 ON OFF Comparative output H (Hysteresis) H: 1 digit or more H (Hysteresis) H: Fixed H (Hysteresis) Comparative output Lo Hi 0 ON OFF 1 This mode is used for setting comparative output ON and OFF at pressures within the setting range. Window comparator mode Notes: 1) Hysteresis can be fixed to one of eight different levels. 2) “ ” appears in the sub display for comparative output 1, and “ ” appears for comparative output 2. 3 This mode is used for setting comparative output hysteresis to the desired level and for carrying out ON / OFF control. Hysteresis mode 2 Low pressure type Standard type DP-101 DP-102 – 100 kPa 100 kPa 1 MPa 0 kPa <For high pressure> Ideal for applications such as checking reference pressure. Can also be used for simple suction. Resolution: 1/2,000 Response time: 2.5 ms Temperature characteristics: ±0.5 % F.S. Repeatability: ±0.1 % F.S. Vacuum breakdown can also be notified during suction applications! Reference pressure alarm output is possible during reference pressure checking! Comparative output 1 EASY mode Comparative output 2 EASY mode ON OFF ON OFF – 100 kPa 0 kPa P-1 0 kPa P-2 Vacuum breakdown checking Suction checking Comparative output 1 Hysteresis mode Comparative output 2 EASY mode ON OFF ON OFF Lo-1 Hi-1 P-2 Reference pressure checking Alarm output Displays measurements in 0.1 kPa Three output modes are suitable for a wide range of applications |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |