49 / 56 page ![]() ISL28023 FN8389 Rev.6.03 Page 49 of 55 Oct 27, 2022 The external clock pin can accept signal frequencies above 25MHz by programming the system clock frequency such that the internal clock frequency is below 25MHz. Figure 116 illustrates the effects of dividing the external clock frequency on the VSHUNT measurement accuracy. Figures 115 and 116 were generated by applying a DC voltage to the VSHUNT input and measuring the signal by way of an ADC conversion. Overranging It is not recommended to operate the ISL28023 outside the set voltage range. In the event of measuring a shunt voltage beyond the maximum set range (80mV) and lower than the clamp voltage of the protection diode (1V), the measured output reading may be within the accepted range but will be incorrect. Shunt Resistor Selection In choosing a sense resistor, the following resistor parameters need to be considered: the resistor value, resistor temperature coefficient and resistor power rating. The sense resistor value is a function of the full-scale voltage drop across the shunt resistor and the maximum current measured for the application. The maximum measurable range for the VSHUNT input (VINP-VINM) of the ISL28023 is 80mV. The ISL28023 allows the user to define a unique range other than ±80mV. Once the voltage range for the input is chosen and the maximum measurable current is known, the sense resistor value is calculated using Equation 19. In choosing a sense resistor, the sense resistor power rating should be taken into consideration. The physical size of a sense resistor is proportional to the power rating of the resistor. The maximum power rating for the measurement system is calculated as the Vshunt_range multiplied by the maximum measurable current expected. The power rating equation is represented in Equation 20. A general rule of thumb is to multiply the power rating calculated in Equation 20 by 2. This allows the sense resistor to survive an event when the current passing through the shunt resistor is greater than the measurable maximum current. The higher the ratio between the power rating of the chosen sense resistor and the calculated power rating of the system (Equation 20), the less the resistor will heat up in high current applications. The Temperature Coefficient (TC) of the sense resistor directly degrades the current measurement accuracy. The surrounding temperature of the sense resistor and the power dissipated by the resistor will cause the sense resistor value to change. The change in resistor temperature with respect to the amount of current that flows through the resistor is directly proportional to the ratio of the power rating of the resistor versus the power being dissipated. A change in sense resistor temperature results in a change in sense resistor value. Overall, the change in sense resistor value contributes to the measurement accuracy for the system. The change in a resistor value due to a temperature rise can be calculated using Equation 21. Temperature is the change in temperature in Celsius. RsenseTC is the temperature coefficient rating for a sense resistor. Rsense is the resistance value of the sense resistor at the initial temperature. Table 50 is a shunt resistor look up table for select full-scale current measurement ranges (ImeasMax). Table 50 also provides the minimum rating for each shunt resistor. It is often hard to readily purchase shunt resistor values for a desired measurable current range. Either the value of the shunt resistor does not exist or the power rating of the shunt resistor is too low. A means of circumventing the problem is to use two or FIGURE 116. EXTERNAL CLOCK vs EXTERNAL BIT VALUE -8.5 -7.5 -6.5 -5.5 -4.5 -3.5 -2.5 -1.5 -0.5 0.5 0 12345 6789 10 11 12 13 14 15 16 ExtClkDiv BIT VALUE ExtClk FREQUENCY = 45MHz (EQ. 19) R sense V shunt_range Imeas Max TABLE 50. SHUNT RESISTOR VALUES AND POWER RATINGS FOR SELECT MEASURABLE CURRENT RANGES RSENSE/PRATING VSHUNT RANGE (PGA SETTING) ImeasMax 80mV 100µA 800Ω/8µW 1mA 80Ω/80µW 10mA 8Ω/800µW 100mA 800mΩ/8mW 500mA 160mΩ/40mW 1A 80mΩ/80mW 5A 16mΩ/400mW 10A 8mΩ/800mW 50A 1.6mΩ/4W 100A 0.8mΩ/8W 500A 0.16mΩ/40W (EQ. 20) P res_rating Vshunt_range Imeas Max (EQ. 21) R sense R sense Rsense TC Temperature |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |