công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

AMC0106M05 bảng dữ liệu(PDF) 26 Page - Texas Instruments

tên linh kiện AMC0106M05
Giải thích chi tiết về linh kiện  AMC0106M05 Precision, ±50mV Input, Functionally Isolated, Delta-Sigma Modulator With External Clock
PDF  35 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  TI2 [Texas Instruments]
Trang chủ  https://www.ti.com
Logo TI2 - Texas Instruments

AMC0106M05 bảng dữ liệu(HTML) 26 Page - Texas Instruments

Back Button AMC0106M05 Datasheet HTML 22Page - Texas Instruments AMC0106M05 Datasheet HTML 23Page - Texas Instruments AMC0106M05 Datasheet HTML 24Page - Texas Instruments AMC0106M05 Datasheet HTML 25Page - Texas Instruments AMC0106M05 Datasheet HTML 26Page - Texas Instruments AMC0106M05 Datasheet HTML 27Page - Texas Instruments AMC0106M05 Datasheet HTML 28Page - Texas Instruments AMC0106M05 Datasheet HTML 29Page - Texas Instruments AMC0106M05 Datasheet HTML 30Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 26 / 35 page
background image
7.2.3 Application Curve
The effective number of bits (ENOB) is often used to compare the performance of ADCs and ΔΣ modulators.
Figure 7-3 shows the ENOB of the AMC0106M05 with different oversampling ratios.
1
10
100
1000
OSR
0
2
4
6
8
10
12
14
16
sinc1
sinc2
sinc3
G013
Figure 7-3. Measured Effective Number of Bits vs Oversampling Ratio
7.3 Best Design Practices
Place a minimum 10nF capacitor at the device input (from INP to INN). This capacitor helps avoid voltage droop
at the input during the sampling period of the switched-capacitor input stage.
Do not leave the inputs of the AMC0106M05 unconnected (floating) when the device is powered up. If either
modulator input is left floating, the output bitstream is not valid.
Connect the high-side ground (AGND) to INN, either by a hard short or through a resistive path. A DC current
path between INN and AGND is required to define the input common-mode voltage. Do not exceed the input
common-mode range, as specified in the Recommended Operating Conditions table. For best accuracy, route
the ground connection as a separate trace that connects directly to the sense resistor. Do not short AGND to
INN directly at the device input. See the Layout section for more details.
AMC0106M05
SBASAS7A – AUGUST 2024 – REVISED JUNE 2025
www.ti.com
26
Submit Document Feedback
Copyright © 2025 Texas Instruments Incorporated
Product Folder Links: AMC0106M05



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com