6 / 34 page

1.0 Functional Description
RC96V24DP
1.2 Technical Specifications
Single Device Data/Modem Data Pump
1-4
D96V24DSA
Table 1-1. Configurations, Signaling and Data Rates
Configuration
Modulation
Transmitter Carrier
Frequency (Hz) ±0.01%
Data Rate
(bps)
Baud
Bits Per
Constella-
tion
Sample
Rate
Answer2
Originate2
±0.01%
(Symbols/
Sec)
Symbol
Points
(Samples/
Sec)
Data Modes
V.22 bis
QAM
2400
1200
24003
600
4
16
7200
V.22
DPSK
2400
2400
1200
1200
12003
6003
600
600
2
1
4
2
7200
7200
Bell 212A
DPSK
2400
1200
12003
600
2
4
7200
Bell 103
FSK
2225 M
2025 S
1270 M
1070 S
0-3004
0-3004
1
1
7200
V.21
FSK
1650 M
1850 S
980 M
1180 S
0-3004
0-3004
1
1
7500
V.23 Forward
Channel5
FSK
1300 M
2100 S
1300 M
2100 S
1200
1200
1
1
96005
V.23 Backward
Channel5
FSK
390 M
450 S
390 M
450 S
75
75
1
1
7200
Fax Modes6
V.29
QAM
QAM
QAM
1700
1700
1700
1700
1700
1700
9600
7200
4800
2400
2400
2400
4
3
2
16
8
4
9600
7200
9600
V.27 ter
DPSK
DPSK
1800
1800
1800
1800
4800
2400
1600
1200
3
2
8
4
9600
9600
V.21 channel 2
FSK
1650 M
1850 S
1650 M
1850 S
300
300
1
1
9600
Dial/Call
Progress Mode
600
7200
Tone Generator/
Tone Detector
Mode
600
7200
Notes:
(1) Modulation legend:
QAM
Quadrature Amplitude Modulation
DPSK
Differential Phase Shift Keying
FSK
Frequency Shift Keying
(2) M indicates a mark condition; S indicates a space condition.
(3) Synchronous accuracy = ±0.01%; asynchronous accuracy = -2.5% to +1.0% (+2.3% if extended overspeed is selected).
(4) Value is upper limit for serial (e.g. 0-300).
(5) RC2324DPL only.
(6) RC96V24DP only.
(7) 9600 samples per sec in V.23 FDX Tx75/Rx1200; 7200 samples per second in V.23 FDX Tx1200/Rx75.