9 / 17 page ![]() X80120, X80121 FN8151 Rev 0.00 Page 9 of 17 January 20, 2005 Manual Reset The manual reset option allows a hardware reset of the power sequencing pins. These can be used to recover the system in the event of an abnormal operating condition. Activating the MR pin for more than 5 s sets all of the ViGDO outputs and the RESET output active (LOW). When MR is released (and if all supplies are still at their proper operating voltage) then the ViGDO and RESET pins will be released after their programmed delay periods. Dual Voltage Monitoring X80120 monitors 2 voltage inputs. When the V1MON or V4MON input is detected to be above the input threshold, the respective output (V1GDO or V4GDO) goes inactive (LOW). The ViGDO signal is de-asserted after a delay of 100ms. This delay can be changed on each ViGDO output individually with bits in register CR3. The delay can be 100ms, 500ms, 1s and 5s. Each ViGDO signal remains active until its associated ViMON input rises above the threshold. Fault Detection The X80120 contains a Fault Detection Register (FDR) that provides the user the status of the causes for a RESET pin active (See Table 20). At power-up, the FDR is defaulted to all “0”. The system needs to initialize the register to 09h before the actual monitoring can take place. In the event that any one of the monitored sources fail, the corresponding bit in the register changes from a “1” to a “0” to indicate the failure. When a RESET is detected by the main controller, the controller should read the FDR and note the cause of the fault. After reading the register, the controller can reset the register bit back to all “1” in preparation for future failure conditions. Flexible Power Sequencing of Multiple Power Supplies The X80120 provides several circuits such as multiple voltage monitors, programmable delays, and output drive signals that can be used to set up flexible power monitoring or sequencing schemes system power supplies. Below are two examples: 1. Power Up of Supplies In Parallel Using Programmable Delays. (See Figure 7 and Figure 8). The X80120 monitors several power supplies, powered by the same source voltage, that all begin power up at the same time. Each voltage source is fed into the ViMON inputs to the X80120. The ViMON inputs monitor the voltage to make sure it has reached the minimum desired level. When each voltage monitor determines that its input is good, a counter starts. After the programmed delay time, the X80120 sets the ViGDO signals LOW. The ViGDO signals can be wire ORed together and tied to an interrupt on the microcontroller. Any individual voltage failure can be viewed in the Fault Detection Register. In the factory default condition, each ViGDO output is instructed to go LOW 100ms after the input voltage reaches its threshold. However, each ViGDO delay is individually selectable as 100ms, 500ms, 1s and 5s. The delay times are charged via the SMBus during calibration of the system. 2. Power Up of Supplies Via Relay Sequencing Using Voltage Monitors (see Figure 9 and Figure 10). Several power supplies and their respective power up start times can be controlled using the X80120 such that each of the power supplies will start in a relay sequencing fashion. In the following example, the 1st supply is allowed to power up when the input regulated supply reaches an acceptable threshold. Subsequent supplies power up after the prior supply has reached its operating voltage. This configuration ensures that each subsequent power supply turns on after the preceding supplies voltage output is valid. Again, the X80120 offers programmable delays for each voltage monitor and this delay is selectable via the SMBus during calibration of the system. TABLE 2. ViGDO OUTPUT TIME DELAY OPTIONS TiD1 TiD0 tDELAYi 0 0 100ms (default) 0 1 500ms 1 0 1 secs 1 1 5 secs where i is the specific voltage monitor (i = 1, 4). V4GDO V4MON V1GDO V1MON X80120/21 RESET µC VCC1 FPGA VCC1 ASIC VCC1 RESET VCC2 MR 1.2V 3.3V 5V Power Supplies IRQ On/Off On/Off FIGURE 7. EXAMPLE APPLICATION OF PARALLEL POWER CONTROL |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |