| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
LTM4664 bảng dữ liệu(PDF) 115 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LTM4664 bảng dữ liệu(HTML) 115 Page - Analog Devices |
|
115 / 138 page ![]() LTM4664A 115 Rev. 0 For more information www.analog.com PMBus COMMAND DETAILS This condition is detected by the ADC so the response time may be up to tCONVERT. This command has one data byte. Table 18. Data Byte Contents: TON_MAX_FAULT_RESPONSE, VIN_OV_FAULT_RESPONSE, OT_FAULT_RESPONSE, UT_FAULT_RESPONSE BITS DESCRIPTION VALUE MEANING 7:6 Response For all values of bits [7:6], the LTM4664A: • Sets the corresponding fault bit in the status commands, and • Notifies the host by asserting ALERT pin, unless masked. The fault bit, once set, is cleared only when one or more of the following events occurs: • The device receives a CLEAR_FAULTS command. • The output is commanded through the RUN pin, the OPERATION command, or the combined action of the RUN pin and OPERATION command, to turn off and then to turn back on, or • The device receives a RESTORE_USER_ALL command. • The device receives a MFR_RESET command. • The device supply power is cycled. 00 The PMBus device continues operation without interruption. 01 Not supported. Writing this value will generate a CML fault. 10 The device shuts down immediately (disables the output) and responds according to the retry setting in bits [5:3]. 11 Not supported. Writing this value will generate a CML fault. 5:3 Retry Setting 000 The unit does not attempt to restart. The output remains disabled until the fault is cleared until the device is commanded OFF bias power is removed. 111 The PMBus device attempts to restart continuously, without limitation, until it is commanded OFF (by the RUN pin or OPERATION command or both), bias power is removed, or another fault condition causes the unit to shut down without retry. Note: The retry interval is set by the MFR_RETRY_DELAY command. 2:0 Delay Time XXX Not supported. Values ignored FAULT SHARING Fault Sharing Propagation COMMAND NAME CMD CODE DESCRIPTION TYPE PAGED DATA FORMAT UNITS NVM DEFAULT VALUE MFR_FAULT_ PROPAGATE 0xD2 Configuration that determines which faults are propagated to the FAULT pins. R/W Word Y Reg Y 0x6993 MFR_FAULT_PROPAGATE The MFR_FAULT_PROPAGATE command enables the faults that can cause the FAULTn pin to assert low. The com- mand is formatted as shown in Table 15. Faults can only be propagated to the FAULTn pin if they are programmed to respond to faults. This command has two data bytes. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |