| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ISO6721 bảng dữ liệu(PDF) 28 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
ISO6721 bảng dữ liệu(HTML) 28 Page - Texas Instruments |
|
28 / 54 page ![]() 10.2.3 Application Curve The following typical eye diagrams of the ISO672x-Q1 family of devices indicate low jitter and wide open eye at the maximum data rate of 50 Mbps. Time = 5 ns / div Figure 10-3. Eye Diagram at 50 Mbps PRBS 216 – 1, 5 V and 25°C Time = 5 ns / div Figure 10-4. Eye Diagram at 50 Mbps PRBS 216 – 1, 3.3 V and 25°C Time = 5 ns / div Figure 10-5. Eye Diagram at 50 Mbps PRBS 216 – 1, 2.5 V and 25°C Time = 5 ns / div Figure 10-6. Eye Diagram at 50 Mbps PRBS 216 – 1, 1.8 V and 25°C 10.2.3.1 Insulation Lifetime Insulation lifetime projection data is collected by using industry-standard Time Dependent Dielectric Breakdown (TDDB) test method. In this test, all pins on each side of the barrier are tied together creating a two-terminal device and high voltage applied between the two sides; See Figure 10-7 for TDDB test setup. The insulation breakdown data is collected at various high voltages switching at 60 Hz over temperature. For basic insulation, VDE standard requires the use of TDDB projection line with failure rate of less than 1000 part per million (ppm). For reinforced insulation, VDE standard requires the use of TDDB projection line with failure rate of less than 1 part per million (ppm). Even though the expected minimum insulation lifetime is 20 years, at the specified working isolation voltage, VDE basic and reinforced certifications require additional safety margin of 20% for working voltage. For basic certification, device lifetime requires a safety margin of 30% translating to a minimum required insulation lifetime of 26 years at a working voltage that is 20% higher than the specified value. For reinforced insulation, device lifetime requires a safety margin of 87.5% translating to a minimum required insulation lifetime of 37.5 years at a working voltage that is 20% higher than the specified value. Figure 10-8 shows the intrinsic capability of the isolation barrier to withstand high voltage stress over its lifetime. Based on the TDDB data, the intrinsic capability of the insulation is 1060 VRMS with a lifetime of 220 years in the 8-DWV package and 450 VRMS with a lifetime of >100 years in the 8D package. Other factors, such as package ISO6720-Q1, ISO6721-Q1 SLLSFF5C – JANUARY 2020 – REVISED MARCH 2021 www.ti.com 28 Submit Document Feedback Copyright © 2021 Texas Instruments Incorporated Product Folder Links: ISO6720-Q1 ISO6721-Q1 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |