| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
V62/12615-01XE-R bảng dữ liệu(PDF) 73 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
V62/12615-01XE-R bảng dữ liệu(HTML) 73 Page - Texas Instruments |
|
73 / 98 page ![]() 73 DP83848-EP www.ti.com SLLSEC6E – SEPTEMBER 2012 – REVISED JUNE 2019 Submit Documentation Feedback Product Folder Links: DP83848-EP Detailed Description Copyright © 2012–2019, Texas Instruments Incorporated 5.6.2.11 CD Test and BIST Extensions Register (CDCTRL1) Table 5-28. CD Test and BIST Extensions Register (CDCTRL1), Address 0x1B BIT BIT NAME DEFAULT DESCRIPTION 15:8 BIST_ERROR_CO UNT 0, RO BIST ERROR Counter: Counts number of errored data nibbles during Packet BIST. This value will reset when Packet BIST is restarted. The counter sticks when it reaches its max count. 7:6 RESERVED 0, RW RESERVED: Must be zero 5 BIST_CONT_MOD E 0, RW Packet BIST Continuous Mode: Allows continuous pseudo random data transmission without any break in transmission. This can be used for transmit VOD testing. This is used in conjunction with the BIST controls in the PHYCR Register (0x19h). For 10Mb operation, jabber function must be disabled, bit 0 of the 10BTSCR (0x1Ah), JABBER_DIS = 1. 4 CDPATTEN_10 0, RW CD Pattern Enable for 10Mb: 1 = Enabled 0 = Disabled 3 RESERVED 0, RW RESERVED: Must be zero 2 10MEG_PATT_GA P 0, RW Defines gap between data or NLP test sequences: 1 = 15 µs 0 = 10 µs 1:0 CDPATTSEL[1:0] 00, RW CD Pattern Select[1:0]: If CDPATTEN_10 = 1: 00 = Data, EOP0 sequence 01 = Data, EOP1 sequence 10 = NLPs 11 = Constant Manchester 1s (10MHz sine wave) for harmonic distortion testing 5.6.2.12 Energy Detect Control (EDCR) Table 5-29. Energy Detect Control (EDCR), Address 0x1D BIT BIT NAME DEFAULT DESCRIPTION 15 ED_EN 0, RW Energy Detect Enable: Allow Energy Detect Mode. When Energy Detect is enabled and Auto-Negotiation is disabled via the BMCR register, Auto-MDIX should be disabled via the PHYCR register. 14 ED_AUTO_UP 1, RW Energy Detect Automatic Power Up: Automatically begin power up sequence when Energy Detect Data Threshold value (EDCR[3:0]) is reached. Alternatively, device could be powered up manually using the ED_MAN bit (ECDR[12]). 13 ED_AUTO_DOWN 1, RW Energy Detect Automatic Power Down: Automatically begin power down sequence when no energy is detected. Alternatively, device could be powered down using the ED_MAN bit (EDCR[12]). 12 ED_MAN 0, RW/SC Energy Detect Manual Power Up/Down: Begin power up/down sequence when this bit is asserted. When set, the Energy Detect algorithm will initiate a change of Energy Detect state regardless of threshold (error or data) and timer values. In managed applications, this bit can be set after clearing the Energy Detect interrupt to control the timing of changing the power state. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |