9 / 41 page ![]() ACT88326VA Rev 1.0, 29-May-2018 Innovative PowerTM www.active-semi.com ActiveSwitcherTM is a trademark of Active-Semi. Copyright © 2018 Active-Semi, Inc 9 SYSTEM CONTROL ELECTRICAL CHARACTERISTICS (VIN_IO = 5V, TA = 25°C, unless otherwise specified.) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT Input Supply Voltage Range: AVIN referenced to AGND 2.7 5.5 V UVLO Threshold Falling 2.5 2.6 2.7 V UVLO Hysteresis 100 mV System Monitor (SYSMON) Programmable Range 2.7 4.2 V OV Threshold Rising 5.4 5.75 6.0 V OV Hysteresis 80 200 320 mV Operating Supply Current All Regulators Disabled 10 µA Operating Supply Current All Regulators Enabled but no load 250 µA Thermal Shutdown Temperature rising 140 160 180 °C Thermal Shutdown Hysteresis 30 °C Power Up Delay after initial VIN Time from VIN > UVLO threshold to Internal Power-On Clear (POR) 120 200 µs Startup Delay after initial VIN Time from VIN > UVLO threshold to start of first regulator turning On. (zero delay) 1500 2000 µs Oscillator Frequency 2.13 2.25 2.37 MHz VIN UV Interrupt Threshold Falling Referenced to rising threshold 200 mV VIN UV Threshold Rising Programming Range Rising edge threshold can power up device. Configurable in 100mV steps. 2.7 3.6 4.2 V VIN UV Shutdown Threshold Falling 2.6 V VIN OV Shutdown Threshold Rising 5.75 V VIN OV Shutdown Threshold Falling 5.5 V VIN Deglitch Time UV 100 µs VIN Deglitch Time OV 200 µs Transition time from Deep Sleep (DPSLP) State to Active State Time from GPIOx pin transition to time when the first regulator turns ON with minimum turn on delay configuration. 1 ms Transition time from Sleep State (SLEEP) to Active State Time from I2C command to clear sleep mode to time when the first regulator turns ON with minimum turn on delay configuration. 100 µs Time to first power rail turn off Time from turn Off event to when the first power rail turns off with minimum turn off delay configuration 120 µs Startup Delay Programmable Range ONDLY=00 ONDLY=01 ONDLY=10 ONDLY=11 0 0.25 0.5 1.0 ms Turn Off Delay Programmable Range Configurable in 0.25ms steps 0 7.75 ms nRESET Programmable Range Configurable to 20, 40, 60 or 100ms. 20 100 ms Note 1: All Under-voltage Lockout, Overvoltage measurements are referenced to the AVIN Input and AGND Pins. Note 2: All POK Under-voltage and Overvoltage measurements are referenced to the VIN Input and PGNDx Pins. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |