| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
SSM3515CCBZ-R7 bảng dữ liệu(PDF) 37 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
SSM3515CCBZ-R7 bảng dữ liệu(HTML) 37 Page - Analog Devices |
|
37 / 41 page ![]() Data Sheet SSM3515 Rev. A| Page 37 of 41 Bits Bit Name Settings Description Reset Access 2 RESERVED Reserved. 0x0 R/W [1:0] SLOPE Slope of Threshold Reduction/Battery Voltage Change. 0x1 R/W 00 1:1 Threshold/Battery Reduction. 01 2:1 Threshold/Battery Reduction. 10 3:1 Threshold/Battery Reduction. 11 4:1 Threshold/Battery Reduction. LIMITER CONTROL 3 REGISTER Address: 0x09, Reset: 0x22, Name: Limiter Control 3 Table 30. Bit Descriptions for Limiter Control 3 Bits Bit Name Settings Description Reset Access [7:0] VBAT_INF Battery Voltage Inflection Point. This is the VBAT sense value at which the limiter either activates or starts reducing the threshold. It corresponds to the value that can be read in the VBAT read only status register. To calculate this value in volts, refer to the VBAT Sensing section. Voltage = 3.8 + 12.4 × Decimal Value/255. 0x22 R/W STATUS REGISTER Address: 0x0A, Reset: 0x00, Name: Status Table 31. Bit Descriptions for Status Bits Bit Name Settings Description Reset Access 7 RESERVED Reserved. 0x0 R 6 UVLO_VREG Regulator Undervoltage Fault Status. 0x0 R 0 Normal Operation. 1 Voltage Regulator Fault Condition. 5 LIM_EG Limiter/Gain Reduction Engaged. 0x0 R 0 Normal Operation. 1 Limiter or Gain Reduction has Reduced Gain. 7 0 6 0 5 0 4 0 3 0 2 0 1 0 0 0 [7] RESERVED [0] BAT_W ARN (R) BatteryVoltage W arning 0: BatteryVoltage above VBAT_INF. 1: BatteryVoltage at or below VBAT_INF. [6] UVLO_VREG (R) Regulator Undervoltage Fault Status 0: Normal Operation. 1: Voltage Regulator Fault Condition. [1] OTW (R) Over Temperature Warning Status 0: Normal Operation. 1: Over Temperature Warning Condition. [5] LIM_EG (R) Limiter/Gain Reduction Engaged 0: Normal Operation. 1: Limiter or Gain Reduction has Reduced Gain. [2] OTF (R) Over Temperature Fault Status 0: Normal Operation. 1: Over Temperature Fault Condition. [4] CLIP (R) Clip Detector 0: Normal Operation. 1: Amplifier Clipping Detected. [3] AMP_OC (R) Amplifier Over-Current Fault Status 0: Normal Operation. 1: Amp Over-Current Fault Condition. 7 0 6 0 5 1 4 0 3 0 2 0 1 1 0 0 [7:0] VBAT_INF (R/W) BatteryVoltage Inflection Point |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |