| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
AD7152 bảng dữ liệu(PDF) 20 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7152 bảng dữ liệu(HTML) 20 Page - Analog Devices |
|
20 / 24 page ![]() AD7152/AD7153 Data Sheet Rev. A | Page 20 of 24 DIFFERENTIAL CAPACITIVE INPUT When configured for differential mode (the CAPDIFF bit in the Channel 1 Setup or Channel 2 Setup registers is set to 1), the CDC measures the difference between positive and negative capacitance input. Each of the two input capacitances, CX and CY, between the EXC and CIN pins must be less than 2 pF (without using the CAPDACs) or must be less than 9 pF and balanced by the CAPDACs. Balancing by the CAPDACs means that both CX − CAPDAC(+) and CY − CAPDAC(−) are less than 2 pF. If the unbalanced capacitance between the EXC and CIN pins is higher than 2 pF, the CDC introduces a gain error, an offset error, and nonlinearity error (see Figure 32, Figure 33, and Figure 34). 0x0000 ... 0xFFF0 DATA CAPDIFF = 1 ±2pF CDC EXC CIN(+) CIN(–) CX 0pF TO 4pF CY 0pF TO 4pF CAPDAC(+) OFF CAPDAC(–) OFF Figure 32. CDC Differential Input Mode 0x0000 ... 0xFFF0 DATA CAPDIFF = 1 ±2pF CDC EXC CIN(+) CIN(–) CX 4pF TO 6pF (5 ± 1pF) CY 4pF TO 6pF (5 ± 1pF) CAPDAC(+) 5pF CAPDAC(–) 5pF Figure 33. Using CAPDAC in Differential Mode 0x0000 ... 0xFFF0 DATA CAPDIFF = 1 ±2pF CDC EXC CIN(+) CIN(–) CX 3pF TO 7pF (5 ± 2pF) CY 5pF CAPDAC(+) 5pF CAPDAC(–) 5pF Figure 34. Using CAPDAC in Differential Mode PARASITIC CAPACITANCE TO GROUND DATA CDC EXC CGND1 CIN CGND2 CX Figure 35. Parasitic Capacitance to Ground The CDC architecture used in the AD7152/AD7153 measures CX connected between the EXC pin and the CIN pin. In theory, any capacitance, CGND, to ground should not affect the CDC result (see Figure 35). The practical implementation of the circuitry in the chip implies certain limits and the result is gradually affected by capacitance to ground. See the allowed capacitance to GND in the Specifications table and, Figure 9 through Figure 12. PARASITIC RESISTANCE TO GROUND DATA CDC EXC RGND1 CIN RGND2 CX Figure 36. Parasitic Resistance to Ground The CDC result can be affected by a leakage current from the CX to ground; therefore, the CX should be isolated from the ground. The influence of the leakage current varies with the power supply voltage (see Figure 36). A higher leakage current to ground results in a gain error, an offset error, and a nonlinearity error (see Figure 13 and Figure 14). |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |