Back Button ATS468 Datasheet HTML 7Page - Allegro MicroSystems ATS468 Datasheet HTML 8Page - Allegro MicroSystems ATS468 Datasheet HTML 9Page - Allegro MicroSystems ATS468 Datasheet HTML 10Page - Allegro MicroSystems ATS468 Datasheet HTML 11Page - Allegro MicroSystems ATS468 Datasheet HTML 12Page - Allegro MicroSystems ATS468 Datasheet HTML 13Page - Allegro MicroSystems ATS468 Datasheet HTML 14Page - Allegro MicroSystems ATS468 Datasheet HTML 15Page - Allegro MicroSystems  
Zoom Inzoom in Zoom Outzoom out
 11 / 15 page
background image
Three-Wire True Zero-Speed Differential Peak-Detecting
Sensor IC with Continuous Calibration
ATS468
11
Allegro MicroSystems, LLC
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
Device Electrical
Output, VOUT
Internal Differential
Signal, VPROC
BRP
BOP
BOP
BRP
1
2
3
4
5
Figure 7: Operation of Running Mode Gain Adjust
• Position1. The device is initially powered-on. Self-calibration occurs.
• Position 2. Small amplitude oscillation of the target sends an erroneously small differential signal to the device. The amplitude of VPROC is
greater than the switching hysteresis (BOP and BRP), and the device output switches.
• Position 3. The calibration period completes on the third rising output edge, and the device enters running mode.
• Position 4. True target rotation occurs and the correct magnetic signal is generated for the installation air gap. The established signal gain
is too large for the target rotational magnetic signal at the given air gap.
• Position 5. Running mode calibration corrects the signal gain to an optimal level for the installation air gap.
signal “seen” during the calibration period is not representative of
the amplitude of the magnetic signal for the installed device air
gap (see figure 7). Note that in this mode, the gain can be reduced
but not increased, so this algorithm applies only to instances in
which the magnetic signal amplitude during running is higher
than that during calibration.
Limited Distribution Allegro Confidential



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com