| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
PIC18F4331 bảng dữ liệu(PDF) 169 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PIC18F4331 bảng dữ liệu(HTML) 169 Page - Microchip Technology |
|
169 / 396 page ![]() 2003 Microchip Technology Inc. Preliminary DS39616B-page 167 PIC18F2331/2431/4331/4431 16.1.5 ENTERING INPUT CAPTURE MODE AND CAPTURE TIMING The following is a summary of functional operation upon entering any of the Input Capture modes: 1. After the module is configured for one of the capture modes by setting the Mode Select bits (CAPxM3:CAPxM0), the first detected edge captures Timer5 value and stores it in the CAPx- BUF register. The timer is then reset (depending on the setting of CAPxREN bit) and starts to increment according to its settings, see Figure 16-4, Figure 16-5 and Figure 16-6. 2. On all edges, the capture logic performs the fol- lowing: a) Input Capture mode is decoded and the active edge is identified b) The CAPxREN bit is checked to determine whether Timer5 is reset or not. c) On every active edge, the Timer5 value is recorded in the input capture buffer (CAPx- BUF). d) Reset Timer5 after capturing the value of the timer when CAPxREN bit is enabled. Timer5 is reset on every active capture edge in this case. e) On all continuing capture edge events repeat steps 1 through 4 until the Opera- tional mode is terminated either by user firmware, POR or BOR. f) The timer value is not affected when switch- ing into and out of various input capture modes. 16.1.6 TIMER5 RESET Every Input Capture trigger can optionally reset (TMR5). Capture Reset Enable bit, CAPxREN, gates the automatic Reset of the time base of the capture event with this enable Reset signal. All capture events reset the selected timer when CAPxREN is set. Resets are disabled when CAPxREN is cleared (see Figure 16-4, Figure 16-5 and Figure 16-6). 16.1.7 IC INTERRUPTS There are four operating modes for which the IC module can generate an interrupt and set one of the Interrupt Capture flag bits (IC1IF, IC2QEIF or IC3DRIF). The interrupt flag that is set depends on the channel in which the event occurs. The modes are: • Edge capture (CAPxM3:CAPxM0 = 0001, 0010, 0011 or 0100) • Period measurement event (CAPxM3:CAPxM0 = 0101) • Pulse width measurement event (CAPxM3:CAPxM0 = 0110 or 0111) • State change event (CAPxM3:CAPxM0 = 1000) The timing of interrupt and special trigger events is shown in Figure 16-7. Any active edge is detected on the rising edge of Q2 and propagated on the rising edge of Q4 rising edge. If an active edge happens to occur any later than this (on the falling edge of Q2, for example), then it will be recognized on the next Q2 rising edge. Note: The CAPxREN bit has no effect in Pulse Width Measurement mode. Note: The special event trigger is generated only in the Special Event Trigger mode on CAP1 input (CAP1M2:CAP1M0> = 1110 and 1111). IC1IF interrupt is not set in this mode. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |