15 / 41 page ![]() ZOPT2202 Datasheet © 2016 Integrated Device Technology, Inc 15 September 21, 2016 3.4 Device Operation Modes Table 3.3 Mode Descriptions Mode Number Mode Name Comment 1 Standby Default mode after power-up. In this mode, the oscillator, all internal support blocks, and the ADCs are switched off but I²C communication is fully supported. 2 UVAB_S Active ADC Channels: UVA, UVB2, COMP UVAB_S Mode provides the ZOPT2202’s internal temperature and stray light compensation for the UVA and UVB2 sensor output data. UVAB_S Mode is a standard operation mode of the ZOPT2202 that is available for activation after power-up or any ZOPT2202 reset. It does not require additional initialization commands to be sent before activation. Note: Internal temperature and stray light compensation is based on COMP channel data. Note: The COMP channel is located aside from the sensor matrix. Hence, stray light compensation is not perfectly matched to the UVA and UVB2 sense elements. Temperature compensation is optimum. UVAB_S Mode is activated by setting the LS_EN bit to 1 and set the RawMode_SEL bit to 0 in the MAIN_CTRL register (see section 3.10.1) o Write 02HEX to register 00HEX Internal temperature and stray light compensation is performed following the calculation before sensor data is stored in the output register: o UVA = UVA_raw – COMP o UVB2 = UVB2_raw – COMP 3 UVB_ONLY Active ADC Channels: UVB, UV_COMP UVB_ONLY Mode allows high precision measurements of UVB energy intensity. The sensor response is chosen such that it can be used to calculate the UV index directly. Temperature and stray light compensation for the sensor channel is performed internally via the UV_COMP channel. UVB_ONLY Mode is a standard operation mode of the ZOPT2202 that is available for activation after power-up or any ZOPT2202 reset. It does not require additional initialization commands to be sent before activation. Note: Internal temperature and stray light compensation is based on the UV_COMP channel data. Note: The UV_COMP channel is located within sensor matrix. Hence, this mode provides optimum temperature and stray light compensation for UVB channel. UVB Mode is activated by setting the LS_EN and UVB_ONLY bits to 1 in the MAIN_CTRL register (see section 3.10.1) o Write 0AHEX to register 00HEX Internal temperature and stray light compensation is performed following the calculation before sensor data is stored in the output register: o UVB = UVB_raw – UV_COMP |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |