63 / 87 page ![]() 63 of 87 ELM329L DSA Elm Electronics – Circuits for the Hobbyist www.elmelectronics.com ELM329L to its low power setting. After a delay of 50 msec (which gives the power supplies a chance to settle), pin 16 is then set to its low power level, and then after a further 50 msec, the chip reduces its power needs. Note that while firmware version 1.0 also set M0, M1 and the Control output to a low level while in low power mode, that is not the case beginning with v2.0 - those 3 pins now remain unchanged. The CAN Monitor (new with v2.0) offers another way in which the ELM329 can be switched to the low power mode. This module continually monitors pin 11 for a signal, and can initiate the low power mode if the signal disappears for more than 2 (or 10) minutes. To use this monitor, simply connect pin 11 to pin 24. By default, the module is enabled with a timeout setting of 10 minutes, so is ready to go. Note that the CAN Monitor signal is blocked from causing a switch to the low power mode while the IC is in a monitoring mode (AT MA, DM1 or MP). This feature is provided so that the ELM329 does not power down while you are troubleshooting with the monitor. The third method is very similar in function to the CAN Monitor. It allows automatic switching to the low power mode when there has been no RS232 input for a period of time (a good method if you have a system where the controlling computer may be turned off at any time). This method does not require any wiring changes for the input as the connection is made internally. This monitor provides slightly longer time delays of either 5 or 20 minutes, to allow for the longer time delays that you might encounter with a human operator. The final method that may be used to enter the low power mode is by a low level appearing at the ignition monitor input (pin 15 - IgnMon). It is enabled by setting both b2 and b7 of PP 0E to ‘1’. Note that when connecting to pin 15, care must be taken to not pass excessive current (>0.5 mA) through the internal protection diodes. Typically a circuit like this works well (note that the Schmitt trigger input on pin 15 allows the use of large value filtering capacitors): The ignition/voltage monitor method uses a short internal delay (‘debounce’) timer to be sure that the low level is a legitimate ‘key off’, and not just noise spikes. As with the previous two methods, when the low power mode is initiated, the ELM329 will send an alert message (‘LP ALERT’), wait 2 seconds, and will then begin low power mode. The AT IGN command can always be used to read the level at pin 15, regardless of the setting of the PP 0E enable bits. This may be used to advantage if you wish to manually shut down the IC using your own timing and criteria. Recall that the alternate function for pin 15 is the RTS input which will interrupt any OBD processing that is in progress. So, if the ELM329 reports being interrupted (ie ‘STOPPED’), you can then check the level at pin 15 with the AT IGN command, and make your own decisions as to what should be done. For that matter, you don’t even need to reduce the power based on the input - you might possibly do something entirely different. Having put the ELM329 into low power mode, you will need a means to wake it up. There are several ways in which you may do this (note that it does not have to be the same method that put it into the low power mode). Figure 7 is a block diagram which shows the possible ways. The first way that a wakeup may occur is by the CAN Monitor sensing that there has been a change from no CAN activity to there being activity (this is shown as a ‘rising edge’ condition in the diagram). In addition to this change in CAN activity, you may also require that the CAN input was previously active by setting (PP 0F) bit 3 to 0 (it is set to 1 by default). This bit 3 switch was provided to more or less ensure that the circuit only wakes up on CAN activity if that was the cause of it going to low power mode. PP 0F bit 7 does not have to be set in order for the circuit to ‘wake up’ on CAN activity. The other two ways that may be used to ‘wake’ the circuit are as shown in Figure 7. The first is with an RS232 input that goes to the active (low) level for at least 128 µsec. This may be accomplished by sending a space or @ character if the baud rate is less than about 57.6 kbps. At higher baud rates, it may be more difficult to generate this width, so you might consider temporarily shifting to a lower baud rate, or see if your software can generate a ‘break’ signal. If you are directly connected to a microprocessor, then you might be able to generate a break signal or pulse output in software. Low Power Mode (continued) 14 15 16 +12V switched by the ignition 47K Ω 22K Ω 0.1uF 329 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |