| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
LSM6DS3US bảng dữ liệu(PDF) 62 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
LSM6DS3US bảng dữ liệu(HTML) 62 Page - STMicroelectronics |
|
62 / 104 page ![]() Register description LSM6DS3US 62/104 DocID028476 Rev 4 9.20 CTRL9_XL (18h) Linear acceleration sensor control register 9 (r/w). 9.21 CTRL10_C (19h) Control register 10 (r/w). Table 70. CTRL9_XL register 0(1) 1. This bit must be set to ‘0’ for the correct operation of the device. 0(1 Zen_XL Yen_XL Xen_XL SOFT_EN 0(1) 0(1) Table 71. CTRL9_XL register description Zen_XL Accelerometer Z-axis output enable. Default value: 1 (0: Z-axis output disabled; 1: Z-axis output enabled) Yen_XL Accelerometer Y-axis output enable. Default value: 1 (0: Y-axis output disabled; 1: Y-axis output enabled) Xen_XL Accelerometer X-axis output enable. Default value: 1 (0: X-axis output disabled; 1: X-axis output enabled) SOFT_EN Enable soft-iron correction algorithm for magnetometer(1). Default value: 0 (0: soft-iron correction algorithm disabled; 1: soft-iron correction algorithm disabled) 1. This bit is effective if the IRON_EN bit of MASTER_CONFIG (1Ah) is set to 1. Table 72. CTRL10_C register 0(1) 1. This bit must be set to ‘0’ for the correct operation of the device. 0(1) Zen_G Yen_G Xen_G FUNC_EN PEDO_RST _STEP SIGN_ MOTION_EN Table 73. CTRL10_C register description Zen_G Gyroscope yaw axis (Z) output enable. Default value: 1 (0: Z-axis output disabled; 1: Z-axis output enabled) Yen_G Gyroscope roll axis (Y) output enable. Default value: 1 (0: Y-axis output disabled; 1: Y axis output enabled) Xen_G Gyroscope pitch axis (X) output enable. Default value: 1 (0: X-axis output disabled; 1: X-axis output enabled) FUNC_EN Enable embedded functionalities (pedometer, tilt, significant motion, sensor hub and ironing) and accelerometer HP and LPF2 filters (refer to Figure 7). Default value: 0 (0: disable functionalities of embedded functions and accelerometer filters; 1: enable functionalities of embedded functions and accelerometer filters) PEDO_RST_ STEP Reset pedometer step counter. Default value: 0 (0: disabled; 1: enabled) SIGN_MOTION _EN Enable significant motion function. Default value: 0 (0: disabled; 1: enabled) |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |