12 / 48 page ![]() HT95AXXX Rev. 1.20 12 May 26, 2004 If the stack is full, any other interrupt request will not be acknowledged, even if the related interrupt is enabled, until the stack pointer is decremented. If immediate ser- vice is desired, the stack must be prevented from be- coming full. All these kinds of interrupts have a wake-up capability. As an interrupt is serviced, a control transfer occurs by pushing the program counter onto the stack, followed by a branch to a subroutine at specified location in the pro- gram memory. Only the program counter is pushed onto the stack. If the contents of the register or status register (STATUS) are altered by the interrupt service program which corrupts the desired control sequence, the con- tents should be saved in advance. External interrupt is triggered by a high to low transition of the INT pin (HT95A400/40P,HT95A300/30P, HT95A200/20P) or INT/TMR0 (HT95A100/10P) and the interrupt request flag EIF will be set. When the external interrupt is enabled, the stack is not full and the external interrupt is active, a subroutine call to location 04H will occur. The interrupt request flag EIF and EMI bits will be cleared to disable other interrupts. The Timer/Event Counter 0 interrupt is generated by a timeout overflow and the interrupt request flag T0F will be set. When the Timer/Event Counter 0 interrupt is en- abled, the stack is not full and the T0F bit is set, a sub- routine call to location 08H will occur. The interrupt request flag T0F and EMI bits will be cleared to disable further interrupts. The Timer/Event Counter 1 interrupt is generated by a timeout overflow and the interrupt request flag T1F will be set. When the Timer/Event Counter 1 interrupt is en- abled, the stack is not full and the T1F bit is set, a subroutine call to location 0CH will occur. The interrupt request flag T1F and EMI bits will be cleared to disable further interrupts. The real time clock interrupt is generated by a 1Hz RTC generator. When the RTC time-out occurs, the interrupt request flag RTCF will be set. When the RTC interrupt is enabled, the stack is not full and the RTCF is set, a sub- routine call to location 14H will occur. The interrupt re- quest flag RTCF and EMI bits will be cleared to disable other interrupts. The dialer I/O interrupt is triggered by any edge transi- tion onto HKS pin or a falling edge transition onto HDI pin or a rising edge transition onto HFI pin, the interrupt request flag DRF will be set. When the dialer I/O inter- rupt is enabled, the stack is not full and the DRF is set, a subroutine call to location 18H will occur. The interrupt request flag DRF and EMI bits will be cleared to disable other interrupts. Note: 1. If the dialer status is on-hook and hold-line, the falling edge transition onto HDI pin will not generate the dialer I/O interrupt. 2. The HDI input is supported for HT95A400/40P, HT95A300/30P and HT95A200/20P. 3. The dialer I/O interrupt will be disabled when the operation mode is in Idle mode. During the execution of an interrupt subroutine, other in- terrupt acknowledge signals are held until the RETI in- struction is executed or the EMI bit and the related interrupt control bit are set to 1 (if the stack is not full). To return from the interrupt subroutine, ²RET² or ²RETI² may be invoked. RETI will set the EMI bit to enable an interrupt service, but RET will not. Register Bits Label R/W Function INTC0 (0BH) 0 EMI RW Controls the master (global) interrupt (1=enabled; 0=disabled) 1 EEI RW Controls the external interrupt (1=enabled; 0=disabled) 2 ET0I RW Controls the Timer/Event Counter 0 interrupt (1=enabled; 0=disabled) 3 ET1I RW Controls the Timer/Event Counter 1 interrupt (1=enabled; 0=disabled) 4 EIF RW External interrupt request flag (1=active; 0=inactive) 5 T0F RW Timer/Event Counter 0 request flag (1=active; 0=inactive) 6 T1F RW Timer/Event Counter 1 request flag (1=active; 0=inactive) 7 ¾ RO Unused bit, read as ²0² INTC1 (1EH) 0 ¾ RW Reserved, inhibit using 1 ERTCI RW Control the real time clock interrupt (1=enable; 0=disable) 2 EDRI RW Control the dialer I/O interrupt (1=enable; 0=disable) 3 ¾ RO Unused bit, read as ²0² 4 ¾ RW Reserved, inhibit using 5 RTCF RW Internal real time clock interrupt request flag (1=active; 0=inactive) 6 DRF RW Internal dialer I/O interrupt request flag (1=active: 0=inactive) 7 ¾ RO Unused bit, read as ²0² |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |