công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

AS5171 bảng dữ liệu(PDF) 28 Page - ams AG

tên linh kiện AS5171
Giải thích chi tiết về linh kiện  Accurate angle measurement
PDF  42 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  AMSCO [ams AG]
Trang chủ  http://www.ams.com
Logo AMSCO - ams AG

AS5171 bảng dữ liệu(HTML) 28 Page - ams AG

Back Button AS5171 Datasheet HTML 24Page - ams AG AS5171 Datasheet HTML 25Page - ams AG AS5171 Datasheet HTML 26Page - ams AG AS5171 Datasheet HTML 27Page - ams AG AS5171 Datasheet HTML 28Page - ams AG AS5171 Datasheet HTML 29Page - ams AG AS5171 Datasheet HTML 30Page - ams AG AS5171 Datasheet HTML 31Page - ams AG AS5171 Datasheet HTML 32Page - ams AG Next Button
Zoom Inzoom in Zoom Outzoom out
 28 / 42 page
background image
Page 28
ams Datasheet
Document Feedback
[v1-01] 2016-Feb-17
AS5171 − Application Information
Programming Parameter
The programming has to be performed in communication
mode. If the cust_lock=0, the sensor starts in communication
mode.
The following procedure and the block diagram are showing
the common 2 point calibration. For special calibration
procedure:
AS5171A: Analog output driver calibration
AS5171A/AS5171B: Linearization.
Please go in contact with the ams application team.
Burn and Verification of the OTP Memory
1.
Power on cycle
2.
Move magnet to the first mechanical start position
3.
Reset the DSP. Writing 0x20 into Reg(0x0023)
4.
Read out the measured angle from ANGLECORDIC
register: T1 Value
5.
Moving of magnet to the second mechanical position
(stop position)
6.
Read out the measured angle from ANGLECORDIC
register: T2 Value
7.
Write T1,T2 and all other transfer parameter into the
DLL: Calculation of GAIN, Offset, BP, Clamping
8.
Write reg(0x000A) to reg (0x001E) with the custom
settings and the calculated values from point 7. -->
AS5171 Settings
9.
Read reg(0x000A) to reg (0x001E) ---> Read register
step 1
10. Comparison of AS5171 settings with content of read
register step 1
11. If point 10 is correct: Decision: pass 2 function
(measurement verification) or programming.
Programming sequence starts with point 12.
12. Write reg(0x000A) to reg (0x001E) with the custom
settings and the calculated values from point 7 +
customer lock Bit. --> AS5171 Settings_Prog
13. Read reg(0x0000) to reg (0x001D) ---> Read register
step 2
14. Calculation of Signature Byte out of Read register step
2 content: Signature Byte
15. Write 8Bit Signature to reg(0x001E)
16. Write reg(0x000A) to reg (0x001E) with the custom
settings and the calculated values from point 7 +
customer lock Bit + Signature byte. --> AS5171
Settings_Prog_final



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com